13-25-607 Page 45
Compressor, air/oil sump and all piping and tubing may be at high temperature
during and after operation.
Do not attempt inspection or cleaning of air-cooled heat exchangers until
cooling fan has stopped rotating. Disconnect lockout and tag out package from
power supply.
Air-cooled heat exchanger cores are fabricated from aluminum. Do not use
caustic liquids to cleanse core or permanent damage will take place.
1. Be sure the unit is completely off and that oil reservoir is depressurized.
2. Open and/or remove enclosure door panels opposite the cooler assembly
– See Figure 6- 2, see
page 46 for details.
3. Inspect core area. If blocked with debris, use a moderate (e.g., 100psi) source of compressed air
while directing nozzle (pointed to outer core finned surface) to dislodge debris and clean. Vacuum
(applied from inner finned core surface) can also be employed to clean the surfaces.
4. Remove all loose debris from inner surfaces of the enclosure, including the main cooling fan area
and its pre-filter, after cleaning process is complete.
5. Re-install the removed enclosure door panels.
Summary of Contents for APEX15-18A
Page 2: ......
Page 31: ...13 25 607 Page 29 Figure 4 6 WIRING DIAGRAM VS 575 VOLT 307UCC546 A Ref Drawing Page 1 of 4...
Page 32: ...13 25 607 Page 30 Figure 4 7 WIRING DIAGRAM VS 575 VOLT 307UCC546 A Ref Drawing Page 2 of 4...
Page 33: ...13 25 607 Page 31 Figure 4 8 WIRING DIAGRAM VS 575 VOLT 307UCC546 A Ref Drawing Page 3 of 4...
Page 34: ...13 25 607 Page 32 Figure 4 9 WIRING DIAGRAM VS 575 VOLT 307UCC546 A Ref Drawing Page 4 of 4...
Page 37: ...13 25 607 Page 35 Figure 4 10 PIPING AND INSTRUMENTATION ILLUSTRATION 301UCC797 F Ref Drawing...
Page 60: ...13 25 607 Page 58 Figure 9 6 Compressor Module Hardware 308UCC810 C Ref Drawing Page 1 of 1...
Page 69: ......