13–8–606 Page 11
Length of Inlet Line
Diameter of Pipe Size
0 to 10 Feet (0 to 3 Meters)
Same as Compressor Inlet Opening
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 to 17 Feet (3 to 5 Meters)
One Size Larger Than Inlet Opening
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 to 38 Feet (5 to 11.5 Meters)
Two Sizes Larger Than Inlet Opening
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 2–4 – INLET LINE LENGTHS
CONTROL PIPING – Control piping is not necessary
since the Electra–Screw
R
unit is factory wired and
piped for the control system specified.
INLET LINE – Where an inlet line is used between the
air filter and the compressor, it must be thoroughly
cleaned on the inside to prevent dirt or scale from en-
tering the compressor. If welded construction is
used, the line must be shot blasted and cleaned to
remove welding scale. In either case, the inlet line
must be coated internally by galvanizing or painting
with a moisture and oil–proof sealing lacquer. Up to ten
(10) feet (3 meters) in length, the inlet line should be the
full size of the inlet opening on the compressor. If an
extra–long line is necessary, the pipe size should be in-
creased according to Inlet Line Length Chart
FIGURE 2–4.
HEAT EXCHANGER
Approx.
Water Temperature to Heat Exchanger
Water Pressure
Gallons/minute
Maximum
Drop @ 90
_
F
Water Flow
Water Temp.
HP
Model
60
_
F.
70
_
F.
80
_
F.
90
_
F.
GPM*
PSI
60 HP
EDFSKB
5.0
6.2
8.3
12.5
40.8
2.0
75 HP
EDFSLB
6.9
8.6
11.5
17.2
40.8
1.5
100 HP
EDHSMB
9.2
11.5
15.3
22.9
40.8
5.0
* Flows exceeding “Maximum Water Flow” will cause severe erosion and will void unit warranty.
FIGURE 2–5 – HEAT EXCHANGER (OIL COOLER) APPROXIMATE WATER FLOW
AFTERCOOLER
Approx.
Water Temperature to Heat Exchanger
Water Pressure
Gallons/minute
Maximum
Drop @ 90
_
F
Water Flow
Water Temp.
HP
Model
60
_
F.
70
_
F.
80
_
F.
90
_
F.
GPM*
PSI
60 HP
EDFSKB
.8
1.0
1.4
2.1
26.0
75 HP
EDFSLB
1.2
1.5
2.0
3.0
26.0
100 HP
EDHSMB
1.7
2.1
2.8
4.1
26.0
* Flows exceeding “Maximum Water Flow” will cause severe erosion and will void unit warranty.
FIGURE 2–6 – AFTERCOOLER APPROXIMATE WATER FLOW
Less than 1 PSI
for any flow rate
shown in the table.
Summary of Contents for EDF-KB
Page 14: ...13 8 606 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 15: ...13 8 606 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 34: ...13 8 606 Page 26 FIGURE 4 10 WIRING DIAGRAM FULL VOLTAGE DUAL CONTROL 208EDF546 Ref Drawing...
Page 36: ...13 8 606 Page 28 FIGURE 5 1 FLOW DIAGRAM 204EDF797 Ref Drawing...
Page 58: ......