13--8--625
Page 43
SYMPTOM
POSSIBLE CAUSE
REMEDY
Oil Carry--Over (Continued)
7.
Inoperative minimum
7.
Replace seals in valve.
pressure valve.
8.
Operation at elevated
8.
Reduce temperature. See
discharge temperatures.
High Discharge Air
Temperature, page 41,
this section.
9.
Water condensate in oil.
9.
Check oil reservoir tempera--
ture and if low, change
thermal mixing valve element
to higher temperature.