13-17-621 Page 21
Table 9: RS485 (X02)
RS485 Connections
Pin
Signal Name
1
B(+) - DATA
2
A(-) - DATA
3
C - GND
RS485 Interface (X03)
Only shielded cable must be used. Available only with IO Modules TEN014983 & TEN14980.
Figure 17 below shows the connector (GD part
TEN014971)
used for RS485 connection and Table 9 for
connector pin number to signal details.
Figure 17: RS485 (X03)
CAN BUS (X04)
Only shielded cable must be used for CAN bus connection. Figure 18 below shows the connector (GD
part
TEN014972
) used for CAN bus connection and Table 10 for connector pin to signal details.
Figure 18: CAN bus (X04)
Table 10: CAN bus (X04)
CAN bus Connections
Pin
Signal Name
1
CAN_H
2
CAN_L
3
GND
2.3.2.5 Terminal Block Connections:
For all cables, a mounting clip is provided on the left and right side of the housing for strain relief and shield
connection. The use of cable ties is recommended.
Digital Input (X05)
Figure 19 below shows the connector (GD part
TEN014973
) used for X05 Digital Input connection and Table
11 for connector pin to signal details.