13-8-619 Page 14
SECTION 3
STARTING & OPERATING PROCEDURES
PRESTART-UP INSTRUCTIONS
- A new unit as received from the factory has been prepared for
shipping only. Do not attempt to operate the unit until checked and serviced as follows:
1.
Compressor Oil
- The oil must be checked before starting the unit and every 8 hours of operation.
For instructions on checking the oil and the proper oil level, refer to “Compressor Oil Filter”,
SECTION 5, page 29.
Do not mix different type oils. Unit is shipped filled with Gardner Denver AEON 4000 Lubricating
Coolant which is suitable for the first 4000 hours under normal operating conditions. AEON 9000 SP
is also available. Check the decal on the reservoir to be sure which lubricant is in the machine.
REPLACE OIL FILTER EVERY 1000 HOURS.
NOTICE
Regular maintenance and replacement at required intervals of the oil filter, air
filter and air/oil separator is necessary to achieve maximum service and
extended drain intervals of AEON 4000 lubricant. Use only genuine Gardner
Denver filters designed and specified for this compressor.
DANGER
Always stop the unit and release air pressure before removing oil filler plug.
Failure to release pressure may result in personal injury or death.
2.
Air Filter
- Inspect the air filter to be sure it is clean and tightly assembled. Refer to SECTION 6,
page 34 for complete servicing instructions. Be sure the inlet line, if used, is tight and clean.
3.
Piping
– Refer SECTION 2, page 11 “Discharge Service Line” and make sure all piping meets all
recommendations.
4.
Electrical
- Check the wiring diagrams furnished with the unit to be sure it is properly wired. See
Figure 4-3, page 23 for general wiring diagrams and SECTION 2, page 11 for “Electrical Wiring”.
5.
Grounding
- Unit must be properly grounded according to Section 250 of the National Electrical
Code.
WARNING
Failure to properly ground the compressor package could result in controller
malfunction.
6.
Rotation
- Check for correct motor rotation by bumping the starter using the ON/OFF switch.
Compressor drive shaft rotation must be counterclockwise facing the compressor sheave.
Summary of Contents for INTEGRA EFB99A
Page 9: ...13 8 619 Page 2 300EFB797 A Ref Drawing Figure 1 2 COMPRESSOR ILLUSTRATION...
Page 12: ...13 8 619 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 13: ...13 8 619 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 30: ...13 8 619 Page 23 300EFB542 C Ref Drawing Figure 4 3 WIRING DIAGRAM...