13-8-619 Page 28
6.
Machine should then be run normally; however, total run time after the initial changeout should be 50
percent of normal anticipated service life of the new lubricant.
- Drain all lubricant from system, change filter
and separator, and replace with full charge of
the new lubricant.
7.
Subsequent lubricant changeouts should be at normal intervals.
CAUTION
Improper equipment maintenance with use of synthetic lubricants will damage
equipment. Oil filter and oil separator change intervals remain the same as for
AEON 4000. See Maintenance Schedule, page 38.
DANGER
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
WARNING
High temperature operation can cause damage to equipment or personal injury.
Do not repeatedly restart the unit after high temperature stops operation. Find
and correct the malfunction before resuming operation.
WARNING
All materials used in Gardner Denver compressor units are compatible with
AEON 9000 SP Lubricating Coolant. Use caution when selecting downstream
components such as air line lubricating bowls, gaskets and valve trim.
AEON 9000 SP Synthetic Lubricant is not compatible with low nitrile Buna N or
acrylic paints. AEON 9000 SP is compatible with most air system downstream
components.
Material Safety Data Sheets (MSDS) are available for all AEON lubricants from your authorized Gardner
Denver distributor or by calling (901) 363-6100.
Summary of Contents for INTEGRA EFB99A
Page 9: ...13 8 619 Page 2 300EFB797 A Ref Drawing Figure 1 2 COMPRESSOR ILLUSTRATION...
Page 12: ...13 8 619 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 13: ...13 8 619 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 30: ...13 8 619 Page 23 300EFB542 C Ref Drawing Figure 4 3 WIRING DIAGRAM...