13-8-621 Page 13
ELECTRIC MOTOR GREASE RECOMMENDATIONS (-30
°
TO 50
°
C)
MANUFACTURER TRADE
NAME
CHEVRON SRI
#2
SHELL DOLIUM
R
EXXON UNIREX
#2
EXXON POLYREX
ELECTRIC MOTOR REGREASING INTERVAL
Type of
Service
Typical
Rating
Relubrication Interval
Up to 150 HP (112 KW)
18 Months
Standard
One or Two Shift Operation
Above 150 HP (112 KW)
12 Months
Up to 150 HP (112 KW)
9 Months
Severe Continuous
Operation
Above 150 HP (112 KW)
6 Months
Up to 150 HP (112 KW)
4 Months
Very Severe
Dirty Locations, High Ambient
Temperature
Above 150 HP (112 KW)
2 Months
Summary of Contents for INTEGRA EFC99A
Page 9: ...13 8 621 Page 2 Figure 1 2 COMPRESSOR ILLUSTRATION 302EFC797 A Ref Drawing...
Page 12: ...13 8 621 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 13: ...13 8 621 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 29: ...13 8 621 Page 22 4 3 WIRING DIAGRAM 300EFC546 B Ref Drawing Page 1 of 2...