13-8-621 Page 31
DANGER
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
DANGER
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
1. Stop unit and be sure no air pressure is in the oil reservoir.
2. Disconnect, tag and lock out the power supply to the starter.
3. Remove the spin-on element.
4. Clean the gasket face of the filter body.
5. Coat the new element gasket with clean lubricant used in the unit.
6. Screw new element on filter body and tighten clockwise by hand 3/4 turn after contact. DO NOT
OVERTIGHTEN ELEMENT.
7. Reset the filter life setting to 1000 hours, see “Maintenance Adjustments” in Controller Operating and
Service Manual.
8. Run the unit and check for leaks.
Figure 5-5 – OIL FILTER
Summary of Contents for INTEGRA EFC99A
Page 9: ...13 8 621 Page 2 Figure 1 2 COMPRESSOR ILLUSTRATION 302EFC797 A Ref Drawing...
Page 12: ...13 8 621 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 13: ...13 8 621 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 29: ...13 8 621 Page 22 4 3 WIRING DIAGRAM 300EFC546 B Ref Drawing Page 1 of 2...
Page 30: ...13 8 621 Page 23 300EFC546 B Ref Drawing Page 2 of 2...