For aluminum oil coolers, do not use any cleaning solution that is not
compatible with aluminum. Use of improper solution may result in damage to
the cooler.
Figure 2-1 – TYPICAL COMPRESSOR ROOM
Minimum Air Flow* For Compressor
And Cooling (cubic Feet/Minute)
Air
Cooled
All Models
4800 cfm
* 80
°
F Inlet Air
Figure 2-2 – AIR FLOW CHART
FOUNDATION
- The rotary screw compressor requires no special foundation, but should be mounted on
a smooth, solid surface. Whenever possible install the unit near level. Temporary installation may be
made at a maximum 5
°
angle lengthwise or 5
°
sidewise. Mounting bolts are not normally required.
However, installation conditions such as piping rigidity, angle of tilt, or danger of shifting from outside
vibration or moving vehicles may require the use of mounting bolts and shims to provide uniform support
for the base. Belt alignment and tension should be checked after installation. (For information on belt
alignment and tension, see SECTION 7, page 49.
OIL RESERVOIR DRAIN
- The oil drain is piped from the bottom of the reservoir to the side of the frame.
This drain is approximately 20 inches above the floor level.
Summary of Contents for INTEGRA EFD99E
Page 11: ...13 20 604 Page 10 Figure 1 2 COMPRESSOR ILLUSTRATION 300EFD797 B Ref Drawing ...
Page 30: ...13 20 604 Page 29 Figure 4 3 WIRING DIAGRAM FULL VOLTAGE 308EDE46 A Ref Drawing Page 1 of 2 ...
Page 31: ...13 20 604 Page 30 308EDE46 A Ref Drawing Page 2 of 2 ...
Page 32: ...13 20 604 Page 31 Figure 4 4 WIRING DIAGRAM WYE DELTA 309EDE546 A Ref Drawing Page 1 of 2 ...
Page 33: ...13 20 604 Page 32 309EDE546 A Ref Drawing Page 2 of 2 ...
Page 34: ...13 20 604 Page 33 Figure 4 5 WIRING DIAGRAM LESS STARTER 310EDE546 A Ref Drawing Page 1 of 2 ...
Page 35: ...13 20 604 Page 34 310EDE546 A Ref Drawing Page 2 of 2 ...
Page 59: ......