13-20-604 Page 20
The compressor starts and stops automatically. Automatic restarting can
cause injury or death. Open, lockout and tagout main disconnect and any other
circuits before servicing the unit.
The enclosure doors must be in place and fastened down to keep the
compressor package from overheating when the compressor is running.
STARTING THE UNIT
- Observe the following starting procedures:
After an emergency stop, be sure that the pressure in the air/oil reservoir is less
than 5 psig. Wait one minute or more before restarting.
The controller has an automatic start/stop sequence built in. You do NOT need
to close the air service valve. Closing the air service valve on start-up or prior
to shutdown will cause rapid cycling, and could cause a high pressure
shutdown.
Unit Cold:
1.
Open the air service valve (customer furnished) between the main air system and the check valve on
the package.
2.
Turn on power to the compressor package. To start press STOP/RESET, then press RUN.
3.
Run for approximately five minutes or until the temperature stabilizes.
The unit is equipped with a minimum (70 psig) pressure/check valve. No special procedure is
required to maintain the unit reservoir pressure.
Summary of Contents for INTEGRA EFD99E
Page 11: ...13 20 604 Page 10 Figure 1 2 COMPRESSOR ILLUSTRATION 300EFD797 B Ref Drawing ...
Page 30: ...13 20 604 Page 29 Figure 4 3 WIRING DIAGRAM FULL VOLTAGE 308EDE46 A Ref Drawing Page 1 of 2 ...
Page 31: ...13 20 604 Page 30 308EDE46 A Ref Drawing Page 2 of 2 ...
Page 32: ...13 20 604 Page 31 Figure 4 4 WIRING DIAGRAM WYE DELTA 309EDE546 A Ref Drawing Page 1 of 2 ...
Page 33: ...13 20 604 Page 32 309EDE546 A Ref Drawing Page 2 of 2 ...
Page 34: ...13 20 604 Page 33 Figure 4 5 WIRING DIAGRAM LESS STARTER 310EDE546 A Ref Drawing Page 1 of 2 ...
Page 35: ...13 20 604 Page 34 310EDE546 A Ref Drawing Page 2 of 2 ...
Page 59: ......