13-20-604 Page 42
OIL LEVEL GAUGE
(Figure 5-4, page 42) - The oil level gauge indicates the amount of oil in the air/oil
reservoir. Read oil level only when the unit is shut down and the air/oil mixture has separated. Add oil
only when the oil level is in the bottom red range, below the white range on the gauge (you must use a
flashlight). Drain oil only when the oil level is in the upper red range above the white range on the gauge
(you must use a flashlight).
Figure 5-4 – OIL LEVEL GAUGE, OIL FILL AND OIL DRAIN
MOISTURE IN THE OIL SYSTEM
- In normal humidity and with normal operating temperatures and
pressures, the thermal mixing valve controls the oil temperature and prevents moisture contamination of
the oil. Unusual cooling of the oil reservoir, short loaded cycle in high humidity or malfunctions of the
thermal valve may result in moisture in the oil system which is detrimental to compressor lubrication and
could cause oil carryover. If moisture is observed in the oil reservoir, drain the moisture and correct the
condition causing the accumulation.
See “Compressor Oil System Check”, page 46 and “Thermal Control (Thermostatic Mixing) Valve”, page
44.
COMPRESSOR OIL FILTER
(Figure 1-2, page 10 and Figure 5-5, page 43)
-
This replaceable element
filter is a vital part in maintaining a trouble-free compressor, since it removes dirt and abrasives from the
circulated oil.
Improper oil filter maintenance will cause damage to equipment. Replace filter
element every 1000 hours of operation. More frequent replacement could be
required depending on operating conditions. A filter element left in service too
long may damage equipment.
Summary of Contents for INTEGRA EFD99E
Page 11: ...13 20 604 Page 10 Figure 1 2 COMPRESSOR ILLUSTRATION 300EFD797 B Ref Drawing ...
Page 30: ...13 20 604 Page 29 Figure 4 3 WIRING DIAGRAM FULL VOLTAGE 308EDE46 A Ref Drawing Page 1 of 2 ...
Page 31: ...13 20 604 Page 30 308EDE46 A Ref Drawing Page 2 of 2 ...
Page 32: ...13 20 604 Page 31 Figure 4 4 WIRING DIAGRAM WYE DELTA 309EDE546 A Ref Drawing Page 1 of 2 ...
Page 33: ...13 20 604 Page 32 309EDE546 A Ref Drawing Page 2 of 2 ...
Page 34: ...13 20 604 Page 33 Figure 4 5 WIRING DIAGRAM LESS STARTER 310EDE546 A Ref Drawing Page 1 of 2 ...
Page 35: ...13 20 604 Page 34 310EDE546 A Ref Drawing Page 2 of 2 ...
Page 59: ......