13-20-604 Page 47
SECTION 6
AIR FILTER
Figure 6-1 – AIR FILTER
STANDARD DUTY AIR FILTER
(Figure 6-1) - Replacement instructions are given in the following
sections:
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
The air filter element can not be cleaned or reused.
Filter Element
- The element should be replaced when inspection indicates an accumulation of dirt on
the outside of the element. Inspect every few days until experience determines the proper time interval
for servicing.
To Service:
1.
Be certain the unit is off and that no air pressure is in the air/oil reservoir. The compressor package
will automatically blow down in about 2 minutes.
2.
Close the air service valve located after the compressor package discharge.
3.
Disconnect, lockout and tagout the power supply to the starter.
4.
Remove the air filter cover (Figure 6-1) and remove the old filter elements.
5.
Clean the inside of the air filter housing.
Summary of Contents for INTEGRA EFD99E
Page 11: ...13 20 604 Page 10 Figure 1 2 COMPRESSOR ILLUSTRATION 300EFD797 B Ref Drawing ...
Page 30: ...13 20 604 Page 29 Figure 4 3 WIRING DIAGRAM FULL VOLTAGE 308EDE46 A Ref Drawing Page 1 of 2 ...
Page 31: ...13 20 604 Page 30 308EDE46 A Ref Drawing Page 2 of 2 ...
Page 32: ...13 20 604 Page 31 Figure 4 4 WIRING DIAGRAM WYE DELTA 309EDE546 A Ref Drawing Page 1 of 2 ...
Page 33: ...13 20 604 Page 32 309EDE546 A Ref Drawing Page 2 of 2 ...
Page 34: ...13 20 604 Page 33 Figure 4 5 WIRING DIAGRAM LESS STARTER 310EDE546 A Ref Drawing Page 1 of 2 ...
Page 35: ...13 20 604 Page 34 310EDE546 A Ref Drawing Page 2 of 2 ...
Page 59: ......