Maintenance plan: Service interval A - every 2000 hours run, but no less than annually
Component
Measure
Necessary qualification Carried out
Filter mats cooling air inlet
Check, clean and replace as
necessary.
Maintenance personnel
Condensate drain
Aftercooler, function check.
Maintenance personnel
Electronic control unit
Check for displayed mainte-
nance requirements.
Operator
Chart 8-8: Maintenance plan: Service A
Maintenance plan: Maintenance interval EX every 4,000 hours, but no less than annually
Component
Measure
Necessary qualification Executed
Customer operations log
Check and adhere to operat-
ing parameters.
Operator
Electronic control unit
Check fault statistics.
Operator
General
Maintenance / cleaning
Maintenance personnel
Air filter
Replace air filter
Maintenance personnel
Oil filter
Replace oil filter
Maintenance personnel
Oil fine separator
Replace
Maintenance personnel
Frequency converter cooling
air inlet filter (RS)
Replace.
Maintenance personnel
FLUIDFORCE SCREW WAR-
RANTY LUBRICANT com-
pressor oil
Replace
Maintenance personnel
Moisture sensor replacement
filter cap (RS) + e
Replace
Maintenance personnel
Motor bearing lubrication
Replace LC unit cartridge
(grease cartridge)
Maintenance personnel
Safety valve
Function test at least once a
year
Maintenance personnel
Hoses and pipelines
Check for leaks or as the case
may be, damage.
Maintenance personnel
Electrical wiring
Check connections and condi-
tion.
Electrician
Compressor
Maintain the compressor room
and surroundings clean.
Operator
Dirt trap (only water-cooled
compressors)
Remove sieve and clean
Maintenance personnel
Chart 8-9: Maintenance plan: Service D
Maintenance plan: Maintenance interval C – every 8,000 hours, but at least every two years
Component
Measure
Necessary qualification Executed
Pressure-retaining valve
Replace.
Maintenance personnel
Suction regulator non-return
valve
Replace.
Maintenance personnel
Chart 8-10: Maintenance plan: Service D