When changing oil, drain used oil as completely as
possible, as used oil greatly reduces the service
life of the new oil charge.
You must refrain from mixing different lubrica-
tion oils. When changing oil types, the oil must be
completely drained from the oil circuit.
You can find the maintenance intervals in the
maintenance plan.
Replacement times for the lubrication oil
Operating conditions (e.g. cooling medium temper-
atures), the type of operation and the quality of the
suction air (e.g. dust content, content of gaseous
foreign substances such as SO2, solvent vapours,
etc.) have a significant impact on oil change inter-
vals.
In such instances of usage, the permitted duration
of use of the oil must be checked with the help of
an oil analysis.
NOTE
Catch the used oil, do not allow it to seep into
the ground.
Dispose of according to the regulations! Do not
spill oil! Immediately capture any used oil! En-
sure leak-tightness!
Changing oil
1. Switch main switch OFF and secure to prevent
switching back on.
2. Wait for compressor to cool down
3. Open the enclosure, create access.
4. Open oil filler neck carefully. Allow any
resid-
ual pressure
to be released.
5. Provide an oil collecting vessel.
6. Place oil drain hose over the collecting vessel.
7. Open oil drain valve.
8. Drain oil completely.
9. Close oil drain valve.
10.Top up with oil until the max. mark is reached.
11.Shut oil filler neck.
12.Shut enclosure.
13.Switch on the main switch.
14.Switch on screw compressor for approx. 2 min.
15.Switch off screw compressor.
16.Switch main switch OFF and secure to prevent
switching back on.
17.Open the enclosure.
18.Check the oil level. If necessary, correct oil
level.
19.Shut enclosure.
8.8.4
Oil filter
Fig. 8-8: Oil filter
WARNING
Risk of scalding
Risk of scalding by hot oil.
➯
Only change the oil when the com-
pressor is stationary and depres-
surised.
➯
Caution when draining hot oil.
The compressor is equipped with two oil filters.
The oil filter elements must be changed, if the
message [
Service due
] or [
Oil filter
] is displayed
on the electronic control unit.
Replacing oil filter elements
1. Switch main switch OFF and secure to prevent
switching back on.
2. Wait for compressor to cool down
3. Open the enclosure, create access.
4. Release the filter elements (for direction of ro-
tation see illustration).
5. Insert new filter elements.
6. Shut enclosure.