L90-L110 L90e-L110e
50Hz, air-cooled "A” + water-
cooled "W"
L90 + L90e
L110 + L110e
Cooling air outlet temperature above
ambient temperature
"A" [°C]
27
32
Residual pressure at ambient temper-
ature
"A" [Pa]
110 / 80
[35 °C / 45 °C]
80/ 40
[35 °C / 45 °C]
Cooling water quantity
"W" [l/min]
90
@ ΔT = 17K
@ Δp = 0.8 bar
125
@ ΔT = 14K
@ Δp = 1.4 bar
Cooling water inlet temperature
"W" [°C]
min. 5 / max. 35
Cooling water outlet temperature
"W" [°C]
max. 55
Cooling water pressure
"W" [bar]
max. 10
Cooling water connections
"W"
EN 10226-1 Rp 11/4 (DIN 2999-R 1 1/2)
Total oil quantity
[l]
63
Compressed air connection
EN 10226 R 2 1/2 (DIN 2999-R 2 1/2)
Weight
[kg]
"A" = 2447
"W" = 2311
"A" = 2532
"W" = 2396
Dimensions L x W x H
[mm]
2290 x 1327 x 2039
Chart 9-3: Technical Data; L90-L110 + L90e-L110e , 50Hz, air-cooled "A", water-cooled "W"
*)
Data measurement and specification as per ISO1217 fourth edition, Appendix C & E and under the following con-
ditions:
Air suction pressure: 1 bar a / 14.5 psia
Air suction temperature: 20°C / 68°F air humidity: 0% (dry)
**)
Measured in an open area as per ISO 2151, tolerance 3 dB(A).
At CompAir, our philosophy is to continually improve our products. We therefore reserve the right to alter technical
data without prior notice.
9.6.2
L90-L110, 60Hz, air-cooled "A", water-cooled "W”
L90-L110
60Hz, air-cooled "A” + water-
cooled "W"
L90
L110
Maximum operating pressure
[bar]
7.5
9
7.5
9
13
Minimum operating pressure
[bar]
5.0
Ambient temperature
[°C]
1 / 45
Volume flow
*)
[m
3
/min]
16.62 16.57
21.90 20.10 16.42
Aftercooler outlet temperature above
ambient temperature
"A" = [°C]
"W" = [°C]
6
7
7
8
8
9
8
8
7
7
Sound pressure level (ISO 2151)
**)
"A" [dB(A)]
"W" [dB(A)]
75
75
77
77
Rated speed of drive motor
[kW]
90
110
Chart 9-4: Technical Data; L90-L110 , 60Hz, air-cooled "A", water-cooled "W”
Summary of Contents for L110 10A V4
Page 73: ......