L132 + L132e
50Hz, air-cooled "A” + water-
cooled "W"
L132 + L132e
Cooling water connections
"W"
EN 10226-1 Rp 11/4 (DIN 2999-R 1 1/2)
Total oil quantity
[l]
63
Compressed air connection
EN 10226 R 2 1/2 (DIN 2999-R 2 1/2)
Weight
[kg]
"A" = 2764
"W" = 2585
Dimensions L x W x H
[mm]
2290 x 1327 x 2039
Chart 9-5: Technical data; L132 + L132e, 50 Hz, air-cooled "[A]", water-cooled "W"
*)
Data measurement and specification as per ISO1217 fourth edition, Appendix C & E and under the following con-
ditions:
Air suction pressure: 1 bar a / 14.5 psia
Air suction temperature: 20°C / 68°F air humidity: 0% (dry)
**)
Measured in an open area as per ISO 2151, tolerance 3 dB(A).
At CompAir, our philosophy is to continually improve our products. We therefore reserve the right to alter technical
data without prior notice.
9.6.4
L132, 60Hz, air-cooled "A", water-cooled "W"
L132
60Hz, air-cooled "A” + water-
cooled "W"
L132
Maximum operating pressure
[bar]
7.5
10
13
Minimum operating pressure
[bar]
5.0
Ambient temperature
[°C]
1 / 45
Volume flow
*)
[m
3
/min]
24.32 22.79 18.62
Aftercooler outlet temperature above
ambient temperature
"A" = [°C]
"W" = [°C]
8
9
8
8
7
7
Sound pressure level (ISO 2151)
**)
"A" [dB(A)]
"W" [dB(A)]
78
76
Rated speed of drive motor
[kW]
132
Total current consumption during load
operation (380V / 460V)
"A" [A]
"W" [A]
305 / 251
292 / 240
Electric motor
IP55 (IE3) - IEC 60034-2-1 ECA Qualifying
Rated speed of drive motor
[rpm]
3000
Rated speed of fan motor
"A" [kW]
W" [kW]
6.6
0.66
Recommended cable cross-section
(380V / 460V)
[mm
2
]
2 x 3 x 70 PE35 /
2 x 3 x 50 PE25
Recommended fuse rating (time-
delayed) (380V + 460V)
[A]
2 x 3 x 200 / 2 x 3 x160
Chart 9-6: Technical data; L132 , 60Hz, air-cooled "A", water-cooled "W"