Clearing a fault
7
January 2017
America
41 /72
Fault
Potential root cause
Remedy
Lubrication system not dispens-
ing, despite voltage being sup-
plied. The plug icon appears on
the display.
Drive and LC not screwed
together properly.
Screw the drive and LC together
until the white triangle on the drive
is fully visible.
Lubrication system is in pressure
cut-off.
OL
Counter-pressure to
lubrication point > 87 psi.
•
Flush lubrication point
(manually or special dispensing
PURGE I)
•
Pressure check if necessary
•
Acknowledge fault by pressing
the SET key.
Lubricant cartridge empty, but no
“LC” message.
LC unit too small for the drive. Use the original LC unit MLS 120
of Gardner Denver.
Chart 7-7: Troubleshooting and clearing faults on the lubricator
Summary of Contents for L160 110A V2
Page 1: ...User manual Screw compressor L160 L290 V2 L160RS L290RS V2 America ZS1149274 03 January 2017...
Page 7: ...Foreword 1 January 2017 America 7 72 1 6 Rating plate Fig 1 1 Rating plate...
Page 69: ...Appendix 9 January 2017 America 69 72...
Page 70: ...9 Appendix 70 72 America January 2017...