8
Maintenance and service
50 / 72
America
January 2017
2
1
Fig. 8-5: Inlet filter and switch cabinet filter fan, water-
cooled system
[1]
Filter fan control
[2]
Inlet filter controller
Fig. 8-6: Louvred grille
Fig. 8-7: Filter element replacement
Change inlet filter
1
Open the mesh cover on the intake filter.
2
Remove dirty filter.
3
Insert new filter.
4
Close louvred grille.
Replacement times for the inlet filter elements
The operating modes and the quality of the suction
air (e.g. dust content) have a significant impact on
the service life of the filter elements.
The filter elements should be inspected for dust
accumulation at least weekly; daily if possible.
If usage scenarios transpire with, for example, a
high rate of dust accumulation, the replacement
intervals must be shortened in relation to the
maintenance plan.
8.6.3
Oil change
1
2
3
4
5
6
Fig. 8-8: Oil filter
[1]
Oil filler neck
[2]
Oil drain
[3]
Oil level indicator
[4]
Min. oil level marking
[5]
Max. oil level marking
[6]
Oil outlet hose
WARNING
Scalding hazard
Scalding hazard from hot oil.
➯
Change the oil only when the
compressor is stopped and not
pressurized.
➯
Use caution when draining out the
hot oil.
Oil must be changed if the message [
Service due
]
is displayed on the electronic control unit.