9
Appendix
64 / 72
America
January 2017
L290 RS,
60Hz, air-cooled "A" + water-cooled "W"
L290 RS
Cooling water inlet temperature
"W" [°F]
min. 41 / max. 95
Cooling water outlet temperature
"W" [°F]
x. 131
Cooling water pressure
"W" [psig]
max. 145
Cooling water connections
"W"
1 1/2-11 1/2 NPT
Total oil volume
[gal]
31.7
Compressed air connection
Flange ANSI B16.5 3" 125lbs
Weight
[lbs]
"A" = 10326
"W" = 9965
Dimensions L x W x H
[in]
114.5 x 81.5 x 86.3
Chart 9-6: Technical data; L290 RSVS290, 60Hz, air-cooled "A", water-cooled "W"
CAUTION
The NEC requires that wire sizes be
determined by using the appropriate
multiplier for the conductor temperature
rating at ambient temperatures other
than 30 ºC (86 °F) and then selecting
the wire that has sufficient ampacity,
after correction, to meet the load
requirements shown in the "NEC
Package Amps @ 30 ºC" column above.
Wire ampacity is to be corrected, not "Package
Amps”. Additional correction multipliers apply
based on more than three conductors in one
conduit.
The appropriate installation and use of
75 ºC (167 °F) and 90 ºC (203 °F) wire is the
responsibility of the electrical professional(s)
performing the installation and must be per NEC,
local and state regulations as allowed.
All of the above recommended minimum wire
sizes are based on all terminal connections being
rated at 75 ºC (167 °F) minimum temperature
rating and copper wire run lengths of 30 m (100 ft)
or less.
Please note that all UL-508A listed control panels
are rated for 40 ºC (104 °F) ambient conditions.