background image

Member

For additional information contact

your local representative or

Gardner Denver Compressor and Pump Division,

1800 Gardner Expressway, Quincy, Illinois 62301

Customer Service Department Telephone:

(800) 682-9868 FAX: (217) 228-8243

Sales and Service in all major cities.

For parts information, contact Gardner Denver,

Master Distribution Center, Memphis, TN

Telephone: (800) 245-4946 FAX: (901) 542-6159

WARRANTY

The manufacturer warrants the product manufactured by it, when properly installed, operated, applied, and
maintained in accordance with procedures and recommendations outlined in manufacturer’s instruction
manuals, to be free from defects in material or workmanship for a period of one (1) year from the date of
shipment to the buyer by the manufacturer or manufacturer’s authorized distributor, or eighteen months from
the date of shipment from the factory, whichever occurs first, provided such defect is discovered and brought
to the manufacturer’s attention within the aforesaid warranty period. The manufacturer will repair or replace
any product or part determined to be defective by the manufacturer within the warranty period, provided such
defect occurred in normal service and not as a result of misuse, abuse, neglect or accident.

The warranty covers parts and labor for the warranty period. Repair or replacement shall be made at the factory
or the installation site, at the sole option of the manufacturer. Any service performed on the product by anyone
other than the manufacturer must first be authorized by the manufacturer.   Normal maintenance items
requiring routine replacement are not warranted. Unauthorized service voids the warranty and any resulting
charge or subsequent claim will not be paid. Products repaired or replaced under warranty shall be warranted
for the unexpired portion of the warranty applying to the original product. The foregoing is the exclusive
remedy of any buyer of the manufacturer’s product. The maximum damages liability of the manufacturer is the
original purchase price of the product or part.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL, OR
STATUTORY, AND IS EXPRESSED IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WAR-
RANTY OF FITNESS FOR A PARTICULAR PURPOSE. THE MANUFACTURER SHALL NOT BE LIABLE FOR LOSS OR DAMAGE
BY REASON OF STRICT LIABILITY IN TORT OR ITS NEGLIGENCE IN WHATEVER MANNER INCLUDING DESIGN, MANUFAC-
TURE OR INSPECTION OF THE EQUIPMENT OR ITS FAILURE TO DISCOVER, REPORT, REPAIR, OR MODIFY LATENT
DEFECTS INHERENT THEREIN. THE MANUFACTURER, HIS REPRESENTATIVE OR DISTRIBUTOR SHALL NOT BE LIABLE
FOR LOSS OF USE OF THE PRODUCT OR OTHER INCIDENTAL OR CONSEQUENTIAL COSTS, EXPENSES, OR DAMAGES
INCURRED BY THE BUYER, WHETHER ARISING FROM BREACH OF WARRANTY, NEGLIGENCE OR STRICT LIABILITY IN
TORT.

The manufacturer does not warrant any product, part, material, component, or accessory

manufactured by others and sold or supplied in connection with the sale of manufacturer’s products.

                                                     01/01/93

AUTHORIZATION FROM THE SERVICE DEPARTMENT IS NECESSARY BEFORE MATERIAL IS

RETURNED TO THE FACTORY OR IN-WARRANTY REPAIRS ARE MADE.

© 2006 Gardner Denver, Inc.

http://www.gardnerdenver.com

respond@gardnerdenver.com

18-2-630  2nd Edition

Litho in U.S.A.

Summary of Contents for RHC Series

Page 1: ...sed air system 4 2 3 Mounting 4 2 4 Piping 4 2 5 Electrical 4 2 6 Air Cooled Models 5 2 7 Compressor tiedown nuts 7 1 2 and 10 horsepower units only 5 3 0 OPERATION 6 3 1 Start up and Shut down Proced...

Page 2: ...When a shipment has been delivered to you in apparent good order but concealed damage is found upon unpacking notify the carrier immediately and insist on his agent inspecting the shipment Fifteen day...

Page 3: ...rature no more water vapor will condense into troublesome liquid In addition the air is filtered of all solid particles three microns and larger Clean dry compressed air leaving the dryer minimizes ma...

Page 4: ...y hole in electrical enclosure If optional disconnect supplied use entry hole in disconnect enclosure 2 0 Installation 2 1 Location A A moderately heated well ventilated area is the best location for...

Page 5: ...sure that voltage to unit is as marked on unit nameplate and on condensing unit baseplate E Air Cooled models remote condensers wire condenser to terminals in dryer electrical enclosure identified on...

Page 6: ...ENERGIZED POWER ON LIGHT ILLUMINATED TWENTY FOUR 24 HOURS BEFORE START UP OF THE REFRIGERATION COMPRESSOR 1 After dryer has been energized at least twenty four 24 hours pull Master switch to on positi...

Page 7: ...ic drains F5 shift F1 Sensor calibration low pressure cutout setting password required F6 shift F2 English or metric unit selection F7 shift F3 Refrigerant low pressure cutout override F8 shift F4 Ele...

Page 8: ...mpressor Solid State Motor SSMP 2MTR Protector Open 2nd Compressor Motor Starter Protector Open MTR STARTER 1MTR Motor Starter Protector Open 2nd Compressor MTR STARTER 2MTR Low oil pressure OIL PRESS...

Page 9: ...9 Typical Wiring Schematic...

Page 10: ...INLET AIR TEMP Optional Indicates inlet air tempera ture is greater than 120 F 49 C 5 LOW EVAP AIR TEMP Optional Indicates air tempera ture in evaporator is below the set point 6 DRAIN LEVEL HIGH Opti...

Page 11: ...ld detergent using a long handled brush or a clean rag attached to a rod Manifold face must be free of dirt and grease to ensure proper O ring seal between top cap and manifold 6 Remove nut 3 and cap...

Page 12: ...on System Check system pressure after unit has been OFF for one 1 hour Com pare this pressure with the refrigeration pressure at ambient temperature They should be the same If system pressure is high...

Page 13: ...scharge valve Check to see that it is fully open 2 Low or high water temperatures at the condenser outlet The condenser is regulated by a pressure actuated water regulating valve supplied by the facto...

Page 14: ...after flushing and wiping further cleaning is desirable The color of this coating varies with water conditions but roughness indicates cleaning tools should be used A set of recommended cleaning tool...

Page 15: ...5 9 3 195 200 34 8 15 1 20 1 1 4 166 160 30 8 9 8 206 880 36 9 18 6 25 1 1 2 213 440 39 5 11 4 278 620 49 7 20 0 30 1 1 2 247 340 45 8 16 6 306 680 54 7 26 0 35 2 1 2 315 820 58 4 11 9 395 460 70 5 15...

Page 16: ...ts kit Reassemble float arm assembly to valve stem assembly using new pivot pin and retainer clip from repair parts kit f Remove valve sleeve 5 from valve stem assembly and replace valve disc 4 with n...

Page 17: ...s positioned in open area of seal ring retainer For 506 series models make sure rod on top of float assembly fits into hole in seal ring retainer as shown in Detail C n Before reassembling shell make...

Page 18: ...efrigerant 4 Water cooled units A Insufficient water flow thru condenser 1 Water regulating valve not adjusted Adjust water regulating valve 2 Dirty water strainer Clean water strainer 3 Water lines t...

Page 19: ...nsor bulb for looseness and correct location 5 Piping vibration Support pipes as required check pipe connections 6 Hissing insufficient refrigerant flow thru Reclaim refrigerant replace strainer expan...

Page 20: ...turer Normal maintenance items requiring routine replacement are not warranted Unauthorized service voids the warranty and any resulting charge or subsequent claim will not be paid Products repaired o...