10
Troubleshooting Guide
If you are having a problem with your compressor, use this table to help determine the cause(s):
Problem
Possible Cause
Corrective Action
Low
Flow
Low
Pressure
Unit Will
Not Start
Motor
Overheats
Loud
Unit
x
High voltage at
compressor
Reduce voltage
x
x
x
x
Low voltage at
compressor
Increase voltage
x
x
x
Damaged valves
Replace flapper valves
x
x
x
Debris in valves
Remove debris and
check for valve damage
x
x
x
Damaged gaskets
Replace gaskets
x
x
x
Worn Cup
Replace connecting rod
assembly or cup
x
x
x
Loose head screws
Tighten head screws
x
Broken fan
Replace fan
x
x
x
Bent motor shaft
Replace entire unit
x
x
Damaged capacitor
Replace capacitor
x
Loose fittings
Tighten fittings
x
x
Insufficient ventilation
in enclosure
Increase air circulation
to enclosure
x
x
Worn bearings
Replace eccentric and
bearing assembley
1
Thermal protector in motor will interrupt current when motor overheats.