Page 22
4990497003 Date: 11/2016
TR20 Installation, Operating & Maintenance Manual
Daily
• Check Air Filter blockage indicator and clean or replace
filter element if required.
Weekly
• Where the compressor is mounted on a vehicle and located
outside, it should be operated for at least 15 minutes each
week (twice a week In damp/cool conditions).
Monthly
• Check gearbox oil level
• Check function of Relief Valve
• Remove air filter and clean inside the casing.
• Check security of compressor and pipe mountings.
500 hours run time or every 12 months (which ever is sooner)
• Change the gearcase oil & filter; see section 5.2
• Drain plugs - clean magnetic part (plug See Fig.6)
Annually
• Examine the internals of the check valve
• Examine pipes and silencers for corrosion and replace as
required
• Replace Air Filter element
• Check Relief Valve function, setting and visually.
Maintenance
5.1
Schedule
5
5.2
Changing the gearcase oil
- see fig 6
1. Remove the magnetic drain plugs and sealing washers (can also remove the fill/
level plugs for faster drainage).
2. Allow the oil to drain into a can for environmental disposal.
3. Change the oil filter.
4. Clean and then refit drain plugs and re-fill the gearcase with approximately 2.5
litres of oil.
5. Ensuring that the TR20 is level, check oil level by removing a fill plug. There should
be a slight leakage of oil with the plug removed.
The relief valve should be
operated every 3 months to clear
the valve seat and check that the
valve is functional.
(Ear protection is
recommended)
NOTE
If the TR20 unit cannot be
completely drained of oil without
tilting the unit, it will be sufficient
to drain as much as possible.
NOTE
500 hours is the maximum oil
change interval.
NOTE
Drive systems must be maintained in accordance with the manufacturers
instructions.