13–11–602 Page i
MAINTAIN COMPRESSOR RELIABILITY AND PERFORMANCE WITH
GENUINE GARDNER DENVER COMPRESSOR
PARTS AND SUPPORT SERVICES
Gardner Denver Compressor genuine parts, engine-
ered to original tolerances, are designed for optimum
dependability ––– specifically for Gardner Denver com-
pressor systems. Design and material innovations are
the result of years of experience with hundreds of differ-
ent compressor applications. Reliability in materials
and quality assurance are incorporated in our genuine
replacement parts.
Your authorized Gardner Denver Compressor distribu-
tor offers all the backup you’ll need. A worldwide net-
work of authorized distributors provides the finest prod-
uct support in the air compressor industry. Your local
authorized distributor maintains a large inventory of
genuine parts and he is backed up for emergency parts
by direct access to the Gardner Denver Machinery Inc.
Master Distribution Center (MDC) in Memphis, Ten-
nessee.
Your authorized distributor can support your Gardner
Denver air compressor with these services:
1.
Trained parts specialists to assist you in selecting
the correct replacement parts.
2.
Factory warranted new and remanufactured
rotary screw air ends. Most popular model reman-
ufactured air ends are maintained in stock at MDC
for purchase on an exchange basic with liberal
core credit available for the replacement unit.
3.
A full line of factory tested AEON
t
compressor lu-
bricants specifically formulated for use in Gardner
Denver compressors.
4.
Repair and maintenance kits designed with the
necessary parts to simplify servicing your com-
pressor.
Authorized distributor service technicians are factory–
trained and skilled in compressor maintenance and re-
pair. They are ready to respond and assist you by pro-
viding fast, expert maintenance and repair services.
For the location of your local authorized Gardner Denver Air Compressor distributor refer to the yellow
pages of your phone directory or contact:
Distribution Center:
Factory:
Gardner Denver Machinery Inc.
Gardner Denver Machinery Inc.
Master Distribution Center
1800 Gardner Expressway
5585 East Shelby Drive
Quincy, IL 62301
Memphis, TN 38141
Phone: (217) 222–5400
Phone: (901) 542–6100
Fax: (217) 223–5897
(800) 245–4946
Fax: (901) 542–6159
REMANUFACTURED AIR ENDS
Whenever an air end requires replacement or repair,
Gardner Denver offers an industry unique, factory re-
manufactured air end exchange program. From its
modern Remanufacturing Center in Indianapolis, IN,
Gardner Denver is committed to supplying you with the
highest quality, factory remanufactured air ends that
are guaranteed to save you time, aggrevation and
money.
Immediately Available
Repair downtime costs you money, which is why there
are over 200 remanufactured units in inventory at all
times, ready for immediate delivery.
Skilled Craftsmen
Our Remanufacturing assembly technicians average
over 20 years experience with air compression products.
Precision Remanufacturing
All potentially usable parts are thoroughly cleaned, in-
spected and analyzed. Only those parts that can be
brought back to original factory specifications are re-
manufactured. Every remanufactured air end receives
a new overhaul kit: bearings, gears, seals, sleeves and
gaskets.
Extensive Testing
Gardner Denver performs testing that repair houses
just don’t do. Magnaflux and ultrasonic inspection spot
cracked or stressed castings, monochromatic light
analysis exposes oil leaks, and coordinate measure-
ment machine inspects to +/– .0001”, insuring that all
remanufactured air ends meet factory performance
specifications.
Warranty
Gardner Denver backs up every remanufactured air
end with a new warranty . . . 18 months from purchase,
12 months from service.
Gardner Denver remanufactured air ends deliver quali-
ty without question . . . year in and year out.
Call Gardner Denver for information on the air end ex-
change program and the name of your authorized dis-
tributor.
Phone Number: 800–245–4946 or
FAX: 901–542–6159
Summary of Contents for TWISTAIR EWDQ D
Page 14: ...13 11 602 Page 4 FIGURE 1 6 AIR WATER SCHEMATIC FIGURE 1 7 OIL SCHEMATIC...
Page 17: ...13 11 602 Page 7 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 18: ...13 11 602 Page 8 DECALS 216EAQ077 206EWD077 222EAQ077 221EAQ077 208EAQ077...
Page 35: ...13 11 602 Page 25 FIGURE 4 2 FLOW CHART FOR SET UP PROGRAMMING...
Page 44: ...13 11 602 Page 34 FIGURE 4 6 CONTROL TUBING SCHEMATIC 206EWD797 A Ref Drawing...
Page 48: ...13 11 602 Page 38 FIGURE 4 10 WIRING DIAGRAM FULL VOLTAGE 202EWD546 REF DRAWING...
Page 49: ...13 11 602 Page 39 FIGURE 4 11 WIRING DIAGRAM WYE DELTA 203EWD546 REF DRAWING...
Page 50: ...13 11 602 Page 40 FIGURE 4 12 AUTO SENTRY ES CONTROLLER DISPLAY...
Page 53: ...13 11 602 Page 43 FIGURE 5 2 FLOW DIAGRAM AIR COOLED 202EWD797 B Ref Drawing...
Page 54: ...13 11 602 Page 44 FIGURE 5 3 FLOW DIAGRAM WATER COOLED 203EWD797 A Ref Drawing...
Page 68: ......