19
)
A for
Home Access
Door Contact
z
When the system is in Away arm
mode, if
Home Access
Door Contact
is triggered, a burglar alarm will be
activated immediately.
z
When the system is in Home arm
mode, if a
Home Access
Door
Contact is triggered, the Control Panel
will start an Entry Delay period to give
enough time to disarm the system.
z
During the Entry Delay or Exit Delay
period, if a
Home Access
Door
Contact is triggered, the Control Panel
will not respond.
)
D for Delay Door Contact
z
When the system is in Away arm /
Home arm mode, if a
Delay
Door
Contact is triggered, a burglar alarm
will be activated immediately.
z
During the Entry Delay or Exit Delay
period, if a
Delay Zone
Door Contact
is triggered, the Control Panel will not
respond.
)
E for
Entry
Door Contact
z
When the system is in Away arm /
Home arm mode, if an
Entry
Door
Contact is triggered, the Control Panel
will start an entry period to give
enough time to disarm the system.
z
After the delay period is expired and
no correct PIN code is entered to
disarm the system, the Control Panel
will respond with a
Burglar Alarm
after 30 secs.
z
When the system is in Alarm off mode,
if an
Entry
Door Contact is triggered,
the Control Panel will make a ding-
dong sound for Door Chime (if
programmed). To program Door
Chime, please refer to section Door
Chime.
)
P for
Away Entry
Door Contact
z
When the system is in Away arm
mode, if an
Away Entry
Door Contact
is triggered, the Control Panel will
start an entry period to give enough
time to disarm the system.
z
After the delay period is expired and
no correct PIN code is entered to
disarm the system, the Control Panel
will respond with a
Burglar Alarm
after 30 secs.
z
When the system is in Alarm off mode,
if an
Away Entry
Door Contact is
triggered, the Control Panel will make
a ding-dong sound for Door Chime (if
programmed).
z
When the system is in Home arm
mode, if an
Away Entry
Door Contact
is triggered, the Control Panel will not
respond.
z
During the Entry Delay or Exit Delay
period, if an
Away Entry
Door Contact
is triggered, the Control Panel will not
respond.
)
H for
24 Hour
Door Contact
z
The
24 Hour
Door Contact is active all
the time and does not have to be
armed or disarmed.
)
F for
Fire
Door Contact
z
The
Fire
Door Contact is active all the
time and does not have to be armed
or disarmed.
)
M for
Medical Emgenercy
Door
Contact
z
A Medical Emg
Door Contact is
active all the time and does not have
to be armed or disarmed.
)
W for
Water
Door Contact
z
Water
Door Contact acts as an
Universal Transmitter and have a
Water leakage sensor connected to it.
z
The
Water
Door Contact is active all
the time and does not have to be
armed or disarmed.
StepA8.
Use the
S
&
T
to make your selection
and confirm by pressing
OK
key. You
are now invited to give a name or
location description to the device to
help understand system events. You
can enter up to 10 letters as you want
for the name followed by
OK
key or
just press
OK
key for no name.
Please see section
Device Naming
for details.
Summary of Contents for CTC-1132
Page 1: ...Installation Programming Operating D D 29 APR 2009...