35
3.10. Control PSS
There are 8 channels Power Switch available
to be used with Control Panel. To open the
Power Switch function you have to turn on the
channel. Please follow the steps to turn on the
channel.
Step 1.
Key in the user code and press
OK
key
while in Disarm mode to access
User’s Menu.
Step 2.
Press the
T
key repeatedly to select
Power Switch
and then press
OK
key
and the start of the log will be
displayed.
C h a n n e l 1
C h a n n e l 2
C h a n n e l 3
C h a n n e l 4
C h a n n e l 5
C h a n n e l 6
C h a n n e l 7
C h a n n e l 8
Step 3.
Select desired Channel number and
press
OK
. The screen will show:
o T u r n O n
T u r n O f f
v
Step 4.
Use
S
&
T
keys to select desired
option.
<
<
N
N
O
O
T
T
E
E
>
>
)
Before adding PSS, any least one
other type of device must be learnt-in
already (e.g. a Door Contact or PIR,
but not Siren, Bell Box, or PSS).
3.11. False Alarm
Management
CTC-1132 has a regulatory false alarm
management facility built-in:
9
Dual-Ply Entry Wanring
9
Sequential Verification Alarm
Reporting
1. Dual-Ply Entry Warning
z
This is to warn the user that an alarm
report to the Emergency Phone Numbers
is about to be made
z
When a zone that is not programmed for
delay is violated during the Entry Delay, or
the correct PIN code was not entered
within the programmed Delay period, a 30-
sec internal alarm is given before an alarm
report is made.
z
If a valid user PIN code is entered within
the 30 seconds, the alarm will be aborted
and the system returns to normal status.
z
If no valid user PIN code is entered, a
burglar alarm will be sent.
2. Mis Operation Reporting
z
This feature is designed to report Disarm
action of those valid User PIN codes
(programmed to
Latchkey.Rpt.Off
) within
90 seconds of the alarm being generated.
z
Automatically, with Latchkey Reporting
being set to
ON
, all arm and disarm
actions of the User PIN code is reported to
the Central Monitoring Station every time.
3. Sequential Verification Reporting
z
A sequential verification alarm report is
generated when a second alarm from a
different Burglar Door Contact or Burglar
PIR is registered within a 30-min period.
z
This Sequential Verification Report will be
sent in addition to the alarm report.
z
Alarms cannot be verified after the Entry
Delay has been initiated.
Summary of Contents for CTC-1132
Page 1: ...Installation Programming Operating D D 29 APR 2009...
Page 2: ......