background image

Part # 1382670 (12/07)

Page 5

SPECIFICATIONS

Gas Type and Connections

MODEL

TYPE

DESCRIPTION

CONNECTIONS

G56T, G56B,  

G56PT and G56PB

Natural or  

Propane gas

Single Deck

3/4 NPT Gas Inlet Line Cord 

Supplied

G56T/B  

G56PTB

Natural or  

Propane gas

Double Deck

(2) 3/4 NPT Gas Inlets  

2 Line Cords Supplied

Model Number Identification

The model numbering system used indicates the input type, 

deck size, intended application, and power module position

EXAMPLE:

G

56

P

T

INPUT G = GAS MODEL

DECK WITH IN INCHES

TYPE OF OVEN; P = PIZZA

NO LETTER = BAKE

POWER MODULE; T = TOP

B = BOTTOM

The model number on your oven is printed on the ratings 

label, located on the side of the control panel housing .

Summary of Contents for Air-Deck G56PT

Page 1: ...oad Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB3 1DQ ENGLAND Telephone 081 561 0433 Fax 081 848 0041 Part 1382670 12 07 200...

Page 2: ...expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of california to cause cancer Operation of this produ...

Page 3: ...ble Unit 8 Concept Of Air Impingement Cooking 9 Operation 9 Possible Settings 10 Air Shutter Adjustments 10 Application Trouble Shooting 11 Adjustments 12 Oven Door 12 Burner flame Adjustment 12 Inter...

Page 4: ...356mm 65 1 4 1657mm 63 1600mm 3 4 NPT REAR GAS INLET 3 4 NPT REAR GAS INLET MODEL INPUT BTU DECK AREA PIZZA CAPACITY MOTOR SHIPPING WT G56PB 80 000 14 0 Sq Ft 6 18 120V 1 60Hz 15 Amps 1 per deck 1000...

Page 5: ...as Double Deck 2 3 4 NPT Gas Inlets 2 Line Cords Supplied Model Number Identification The model numbering system used indicates the input type deck size intended application and power module position...

Page 6: ...iance of the installation with the manufacturer s specifications In addition compliance with the National Fuel Gas code ANSI Z 223 1 1988 NFPA and or Local Code is required to assure safe and efficien...

Page 7: ...s from ridge More than 10 3 meters 3 90cm Min Direct Connection Instructions The G56P T B or double deck may be direct vented to the outside In order to accomplish direct venting and maintain proper o...

Page 8: ...roperly grounded three pronged receptacle Do not cut or remove the grounding prong from this plug INSTALLATION Continued Unit Assembly 1 Before assembly and connection check gas supply and electrical...

Page 9: ...the production of food products It is normal for the unit to smoke while burning off excess oil Washing the deck of the oven with a damp clean cloth and mild soap solution will remove some of the prot...

Page 10: ...ly Closed Fully Open Pre Baked Party Pizza 16 00 20 00 475 500 250 260 Fully Closed Fully Open Air Shutter Adjustments To adjust the dampers loosen wing nut holding damper position with deck and dampe...

Page 11: ...ght 1 Increase cooking time 2 Increase temperature Pizza bottom and Top Too Dark 1 Decrease cooking time 2 Decrease temperature Pizza Bottom Too Dark and Top too Light 1 Increase top air by adjusting...

Page 12: ...ly The spring hook passed through a bracket A 1 4 x 20 nut is on the spring hook forward of the bracket If it is available use a 7 16 deep socket and ratchet to turn the nut clockwise to increase spri...

Page 13: ...he reset or normal operating condition Safety Lockout Time S86 S86D Only The safety lockout timer circuit starts timing the moment the trial for pilot ignition starts When the timing period runs out t...

Page 14: ...ich arcing stops CAUTION Do not touch either stripped end of jumper or stud terminal This is a very high voltage circuit and electrical shock can result Perform the test immediately upon energizing th...

Page 15: ...PRESENT SYSTEM FAILS TO START 4 PILOT BURNER LIGHTS S86 SENSES FLAME CURRENT PILOT BURNER OPERATION OR PILOT BURNER DOES NOT LIGHT S86A OR B TRIAL FOR IGNITION CONTINUES S86C OR D GOES INTO LOCKOUT A...

Page 16: ...COIL THERMOSTAT TRANSFORMER NEUT HOT MOTOR RELAY MOTOR EP SYSTEM HONEYWELL SWITCH CENTRIFUGAL TO ELECTRODE BLUE WHT RED GND PV MV PV MV SB6 HONEYWELL 24V RED RED YEL YEL MOTOR BLK BLK BLK MOTOR RELAY...

Page 17: ...IF NO VOLTAGE REPLACE CONTROL REPLACE CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE CHECK THAT PILOT FLAME COVERS BOTH ELECTRODES IF CHECKS ARE OKAY REPLACE MODULE CHECK FOR 24 V AT TERMINALS 3...

Page 18: ...hould be scraped loose and removed Periodic removal of the deck and Jet Plates is strongly recommended This will enable you to remove any build up of deposits on the Jet Plates and access the oven bot...

Page 19: ...Part 1382670 12 07 Page 19...

Page 20: ......

Reviews: