-17-
090908_Instructions for use RTCS Base- and Wok-Line_E.doc
8
Fault finding/Rectification
The cookers may only be opened by authorized service personnel.
CAUTION
Do not open the cooker!
Dangerous electric voltage inside!
Stop any actions if the heating area (Ceran plate) is cracked or broken, the induction cooker
must be switched off and disconnected from the electric supply. Don’t touch any parts inside
the cooker.
8.1
Fault finding with error code
Number of flashing
signals (Code)
Possible cause
Action to take
E03
- . . . - . . .
Overheated heat sink
Let unit cool down
Check air filter and air flow
Air-cooling
system
obstructed
Verify that air inlet and air outlet
are not obstructed with objects
Clean air filter
E04
- . . . . - . . . .
Overheated cooking zone
Let unit cool down
Check air filter and air flow
E05
-. . . . .-. . . . .-
Error on power switch
Contact service agent
E06
- . . . . . . - . . . . . .
Overheated electronic
Let unit cool down
Check air filter and air flow
Ambient temperature too high
(the cooling system is not able to
keep the cooker in normal
operating conditions)
Verify that no hot air is sucked in
by the fan
Reduce the ambient temperature,
the air inlet temperature must be
lower than 40ºC/110ºF
E07
- . . . . . . . - . . . . . . .
Empty cooked pan
Switch the unit off to reset the
empty cooking detector
E08
- . . . . . . . . - . . . . . . . .
Error on sensing element
Contact service agent
Order of error message: The indicator lamp flashes for an interval of 0,6 sec. The number of
the following short flashes has to be counted and informs about the kind of error
corresponding to the above mentioned code system.
The code will repeat until the error is cancelled.