background image

4

COMBUSTIBLE WALL

MINIMUM CLEARANCE

NON-COMBUSTIBLE WALL

MINIMUM CLEARANCE

ALL MODELS

mm

ins

mm

ins

SIDES

152

6

152

6

BACK

152

6

152

6

INSTALLATION PROCEDURE

GENERAL

1.

 

Carefully remove the unit from the crate.  All packing material must be removed from the
unit.  The protective material covering the stainless steel must be removed immediately after
the unit is installed.

2.

 

Adequate clearance must be provided for servicing, ventilation and proper operation.  The
product must be kept clear of combustible material.

CASTERS

1.

 

The front casters on the unit are equipped with brakes to limit movement of the range without
relying on the electrical connection to limit appliance movement.

2.

 

A restraint can be attached to the unit near the electrical connection. If the restraint is
disconnected, be sure to reconnect it after the range has been returned to its originally
installed position.

COMMISSIONING

Ensure all circuit breakers located behind the access door on the control panel are set to the “ON”
position.

1.

 

Ensure that all controls are in the “OFF” position and turn on the main electrical supply.

2.

 

Operate each section of the unit in accordance with the operating instructions provided in this
manual.

3.

 

Check that the product functions correctly and the voltage supply to the unit does not drop by
more than 5% when all sections are operated simultaneously.

When the operation has been checked, hand the manual to the user or purchaser for retention and
instruct them in the efficient and safe operation of the appliance.

OPERATING INSTRUCTIONS

GRIDDLES

Griddle tops are designed to have food cooked directly on the surface. Do not put pots or pans on
the griddle surface as this will scratch or nick the surface and will result in improper cooking or

Summary of Contents for ECG

Page 1: ...RECT INSTALLATION OR OPERATION OF THE EQUIPMENT TABLE OF CONTENTS GENERAL INFORMATION TECHNICAL SPECIFICATIONS GENERAL INSTALLATION INSTALLATION PROCEDURE COMMISIONING OPERATING INSTRUCTIONS MAINTENAN...

Page 2: ...salt free oil may be applied to prevent further rusting INTRODUCTION The Garland ECG series complies with the standards CSA C22 2 no 109 latest edition the UL197 latest edition and the ANSI NSF 4 lat...

Page 3: ...8 35 8 35 8 62 0 ECG 36R 12 90 240 4 30 4 30 4 30 31 0 31 0 31 0 53 8 17 20 208 5 60 6 00 5 60 48 3 46 6 48 3 82 7 ECG 48R 17 20 240 5 60 6 00 5 60 41 9 40 4 41 9 71 7 21 50 208 6 90 7 30 7 30 59 1 5...

Page 4: ...nd in its normal operational position SITING The base on which the unit is to be sited must be capable of adequately supporting the weight of the appliance and any ancillary equipment Refer to technic...

Page 5: ...disconnected be sure to reconnect it after the range has been returned to its originally installed position COMMISSIONING Ensure all circuit breakers located behind the access door on the control pan...

Page 6: ...ly during heavy use to prevent overflow OPERATING THE GRIDDLE NOTE Ensure the electrical supply to the appliance is turned ON 1 Switch ON main power switch on the control panel 2 Switch ON desired sec...

Page 7: ...LE 1 Using a clean cloth rub a thin and even layer of oil into the griddle surface Oil should be an unsalted shortening or high temperature cooking oil 2 Set the griddle thermostat to 66 C 150 F and h...

Page 8: ...urface and rinse thoroughly with a water and vinegar solution Dry griddle 6 Using a clean cloth rub a thin and even layer of oil into the griddle surface 7 Re season the griddle as detailed above The...

Page 9: ...rried out at regular intervals the frequency of which will vary depending on the installation conditions and usage Usually once per year is adequate Servicing must be carried out by competent persons...

Page 10: ...9...