9.3 M40GSSBP
9.3.1 Fiber 40Gigabit Ethernet Technical Specifications - (40GBase-LR4) Adapters:
IEEE Standard / Network topology:
Fiber Gigabit Ethernet, 40GBase-LR4 (1310nM)
Data Transfer Rate:
40Gbit/s per port
Network ports Cables and Operating
distance:
Single mode fiber:
5000m maximum at 9 um
**
**
Theoretical Distance – Defined as half a distance
Insertion Loss ( Passive: Normal
Mode)
Typical: 1.2 dB
Maximum: 1.6dB
Insertion Loss ( Passive: Bypass
Mode)
Typical: 1.2 dB
Maximum: 1.6dB
Voltage:
12V +/-5%, 5VSB+/-5%, 5V +/-5%
Size:
102.2mm x161.9 mm x 40.5 mm (4.02” x 6.37” x 2”)
Wide x Depth x Height
Operating Humidity:
0%–90%, non-condensing
Operating Temperature:
0°C – 40°C (32°F - 104
F)
Storage Temperature:
-20
C–65
C (-4
F–149
F)
EMC Certifications:
Class B FCC / CE / VCCI /
Safety:
UL
MTBF*:
> 150,000 hours
9.3.2 M40GSSBP and : LED and Connector Specifications
LEDs:
Green LED per port (Network / Monitor)
Activity : LED will blink.
Link : LED will turn on.
Two LED:
Inline Mode – Green LED.
Non Inline Mode :Bypass, TAP, Disconnect – Yellow (Orange) LED.
HB Status LED
Blinking Green LED – HB is active.
LED is off – HB not active.
Connecto
rs:
Network: 2 LC
Monitor: 2 QSFP+