Installation
RTCSmp Built-In Module-Line Dual/Quad Cooktops
Part # 4532415 Rev 1 (12/12/13)
Page 17
4.3.5
Dimensions Guide (Holes/Studs)
Dimensions in mm [inch]
4.4
Coil Carrier Sheet, Ceran Glass and Mounting Frame
The module-line cooktops are to be flush mounted. The cooktop assembly composes of a Ceran glass top, coil
carrier sheet(s), and mounting frame. The glass and coil carrier sheet are to be inserted into the mounting frame.
Please follow all the location, ventilation and clearance requirements listed in this section.
4.4.1
Location & Ventilation
•
Distance from the control unit to the coil carrier sheet: MAX. 31.50” / 80cm.
•
Clearance below the coil carrier sheet/mounting frame: MIN. 3.94” / 10cm. This clearance must be
maintained for installation and service. Ensure this area can be easily accessible for service.
•
MUST NOT install or store any metallic objects or components below the coils.
•
When placed in the vicinity of the coils, objects/components made of steel must be non-magnetic.