Installation
RTCSmp Built-In Module-Line Dual/Quad Cooktops
Part # 4532415 Rev 1 (12/12/13)
Page 23
I.
While holding the coil carrier sheet with the retaining rails, swing the rails back into the original position
and tighten the screws.
J.
The coils and temperature sensors installed on the coil carrier sheet must exert a constant pressure of
5mm to the Ceran glass. This pressure ensures the temperature monitoring to work properly. Do not
allow any gap between the temperature sensors and the glass. You MUST set the pressure correctly.
To adjust the pressure correctly:
i.
Tighten or loosen the M4 screws to adjust the pressure correctly.
ii.
Distance from the underside of the coil carrier sheet to the Ceran glass:
50mm +/- 2mm
.
iii.
Bolts of the coil carrier sheet: protrude
5mm
from the coil carrier sheet.