Document #: G_GO_OM_PYRODECK_4606131 – 12/20
Page 5
INSTALLATION
1. Damage Check: check carton or crate for possible
damage incurred in shipping. After carefully uncrating,
check for “concealed” damage. Report any damage
immediately to your carrier.
2. The correct type of gas for which the unit was
manufactured is noted on the rating plate, and this type
of gas must be used.
3. The gas pressure must be checked when the unit is
installed, to ensure that the unit gas pressure is the same
as specified on the rating plate. If necessary pressure
adjustments can be made at the pressure regulator,
supplied on each unit.
4. Have a qualified gas technician check the gas pressure
to make certain that existing gas facilities (meter, piping,
etc.) will deliver the BTU’s of gas required at the unit with
no more than ½” water column pressure drop. When
checking pressure, be certain that all the equipment on
same gas line is turned to the “ON” position.
5. Make certain that the new piping, joints and connections
have been made in a clean manner and have been
purged, so that the piping compound, chips, etc will not
clog pilots, valves and / or controls. Use pipe joint sealant
that is certified for use with LP gas.
6.
WARNING
; check gas connections for leaks, using soap
solution or similar means. DO NOT CHECK WITH AN OPEN
FLAME.
Rating Plate
All burner-input ratings are shown on the serial plate located
on the right side panel of the appliance.
When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular unit
by the correct model number (including the prefix and suffix
letters and numbers) and the warranty serial number. The
rating plate affixed to the unit contains this information.
We suggest installation, maintenance and repairs should be
performed by your local authorized service agency listed in
your information manual pamphlet.
In the event you have any questions concerning the
installation, use, care or service of the product, write or call
our Product Service Department.
This product must be installed by professional personnel as
specified. Garland products are not approved or authorized
for home or residential use, but are intended for commercial
applications only. Garland will not provide service,
warranty, maintenance or support of any kind other than in
commercial applications.
Gas Connections
The inlet manifold size for connection to the main gas supply
is (1) 3/4”NPT inlet for each deck.
The importance of proper installation of Commercial
Gas Cooking Equipment cannot be over-stressed. Proper
performance of the equipment is dependent, in great part,
on the compliance of the installation with the manufacturer’s
specifications. Installation must conform to local codes
and with the National Fuel Gas Code NFPA 54/ANSI Z223.1,
Natural Gas Installation Code CAN/CGA-B149.1, or the
Propane Installation Code CAN/CGA-B149.2, as applicable,
including:
1. The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi (3.45
kPa)
Before assembly and making gas connections, check gas
supply.
A. The type of gas for which the unit is equipped is stamped
on the data plate located behind lower front panel.
Connect a unit stamped “NAT” only to natural gas;
connect those stamped “PRO” only to propane gas.
B. If it is a new installation, have gas authorities check meter
size and piping to assure that the unit is supplied with a
sufficient amount of gas pressure to operate the unit.
C. If it is additional or replacement equipment, have gas
authorities check pressure to make certain that existing
meter and piping will supply fuel at the unit with not
more than ½” water column pressure drop.
NOTE: When checking pressure be sure that all other
equipment on the same gas line is on. A pressure regulator is
supplied with GARLAND Pizza Ovens. The regulator is preset
to deliver gas at the pressure shown on the rating plate.
Summary of Contents for GPD Series
Page 13: ...Document G_GO_OM_PYRODECK_4606131 12 20 Page 13 Notes...
Page 14: ...Document G_GO_OM_PYRODECK_4606131 12 20 Page 14 Notes...
Page 15: ...Document G_GO_OM_PYRODECK_4606131 12 20 Page 15 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 19: ...Num ro du document G_GO_OM_PYRODECK_4606131 12 2020 Page 14 Remarques...
Page 20: ...Num ro du document G_GO_OM_PYRODECK_4606131 12 2020 Page 13 Remarques...