Electrical Installation
IMPORTANT
Refer to the electrical specifications in chapter
3 Dimensions and Technical Specifications
AND the
markings/instruction labels on the unit
. If the information differs between the data listed in the
manual and the markings on the unit, always follow the markings on the unit.
Check and ensure that the supply voltage and the line current match the specifications given on the
rating plate. A stable mains supply must be provided.
CAUTION
Wrong voltage will damage the induction unit. Follow strictly
the specifications on the rating plate.
The electrical connections must satisfy the national and local electrical codes.
If ground fault current protective switches are used, they must be provided with selective activation and
designed for a minimum fault current of 30mA. Multiple generators with a mains connection must not be
connected to a single fault current protective switch.
Always route sensor and communication cables separately and away from the coil cables.
To manage electromagnetic interference, excess cable length can be dressed and tied in a serpentine or
S pattern, NOT coiled.
To setup the unit for operation:
1.
Ensure the control knob is at the OFF-Position.
ON-Position
Any position where
“0”/Line is not pointing
straight up.
OFF-Position
“0” / Line is pointing
straight up.
2.
Remove all objects from the glass-top and check that the glass-top is neither cracked nor broken.
CAUTION
Do not continue if the glass-top is cracked or broken.
Contact an authorized service agency for assistance.