Installation
RTCSmp Built-In Temperature Controlled Hold-Line
18
Part # 4532286 Rev 3 (6/10/14)
3.
Connecting the components:
A.
Each Induction Generator can connect up to four Heat Retaining Plates. Therefore, there are four
control zones on a Generator: Zone A, Zone B, Zone C, and Zone D.
IMPORTANT
: Connect
ONE
Heat Retaining
PLATE
to
ONE ZONE
only.
Installing 1 Heat Retaining Plate, use any one of the zones.
Installing 2 Heat Retaining Plates and only one control unit: use Zones A, B OR Zones C, D.
Installing 2 Heat Retaining Plates and two control units: use Zones A, C OR Zones B, D.
Installing 3 Heat Retaining Plates, with two control units, use any three of the four zones.
B.
Within each zone, there are two types of connectors:
(i)
coil and
(ii)
sensor.
Use the coil cable to connect the coil connector on the Plate to the corresponding one on the
Generator. Similarly, connect the sensor connectors with the sensor cable provided.
C.
Secure the grounding cables of the Heat Retaining Plates.
D.
Up to two Control Units can connect to one Generator. Use the RJ-45 cable(s) provided to
connect the Control Unit(s) to the Generator.
E.
Control Unit connected to the LEFT connector controls both Zones C and D.
F.
Control Unit connected to the RIGHT connector controls both Zones A and B.
G.
Connect each built-in frame to earth with the respective grounding bolts.
H.
Connect the Generator to the power cable.
4.
Connect the unit to the power supply.
5.
Perform the Function Test. See chapter