Operating Instructions
RTCSmp Built-In Temperature Controlled Hold-Line
22
Part # 4532286 Rev 3 (6/10/14)
6.3
Temperature Control and Display
6.3.1
Configurations and Temperature Control
One RTCSmp HOIN induction generator can control up to four heat retaining plates. Hence, four configurations
are available, ranging from one to four heat retaining plates. For each configuration, one temperature control
switch controls up to two heat retaining plates. When two heat retaining plates are connected to one switch, both
plates would be set to the same set temperature.
Model
Configuration
(Heat Retaining Plate(s), Control Switch(s),
and Induction Generator are shown)
HO IN 450
One switch controls one heat retaining plate.
HO IN 900
Two switches; each controls only one heat
retaining plate.
HO IN 1350
Two switches; one switch controls one heat
retaining plate and the other switch controls two
plates.
HO IN 1800
Two switches; each controls two heat retaining
plates.