Dimensions and Technical Specifications
RTCSmp Built-In Temperature Controlled Hold-Line
Part # 4532286 Rev 3 (6/10/14)
7
3
Dimensions and Technical Specifications
3.1
Rating Plate
The rating plate specifies important information such as model number,
serial number, and electrical specifications. The rating plate is affixed to
the bottom of the generator, by the connectors at the front.
3.2
Nomenclature and Models
Series
Built-In Power (Watt)
Model
HO
= Hold Line
IN
450
(1 heat-retaining plate)
HO IN 450
900
(2 heat-retaining plates)
HO IN 900
1350
(3 heat-retaining plates)
HO IN 1350
1800
(4 heat-retaining plates)
HO IN 1800
3.3
Dimensions
Component
Dimensions (width x length x height)
Generator Housing
11.93”x 12.28”x 5.31” (303 x 312 x 135mm)
Heat-Retaining Plate 12.68”x 12.68”x 2.95” (322 x 322 x 75 mm)
Ceran Glass
12.68”x 12.68”x 0.16” (322 x 322 x 4 mm)
3.4
Electrical Specifications
Model
Voltage
Power
Power Per Heating Plate
HOIN450/900/1350/1800
120 V AC / 1Ph
1800 W / 16A
450W
HOIN450/900/1350/1800
230 V AC / 1Ph
1800 W / 8A
450W
3.5
Operating Conditions
Max. Tolerance of Nominal Supply Voltage
+6 /-10 %
Supply frequency
50/60 Hz
Ingress Protection class
IP X0
Minimal Diameter of Induction Pan
5” (12cm)
Maximum Ambient Temperature
In Storage > -4°F to +158°F (-20°C to +70°C)
In Operation >+ 41°F to +104°F (+5°C to +40°C)
Maximum Relative Air Humidity
In Storage > 10% to 90%
In Operation > 30% to 90%
Set Temperature Range
122-212°F / 50-100°C
Maximum air flow: 56.50cfm / 96m
3
per hour and min. opening: 9.30 sq.in. / 6000mm
2
is required.
3.6
Compliances
North American models
:
ETL listed in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001
CE models
comply with the latest European Norms:
EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)