Page 9
Page 9
V
Veerr 1
1..
6
Pressing
when on the Slot 1 Status Screen of a Copper TAP Module, will bring
up the Duplex Configuration Screen.
=========================
Slot 1 Duplex Configuration
=========================
Current Mode:
Link:
Port A
Port B
Port C
Port D
New Duplex:
Auto
Auto
Auto
Auto
Current Duplex:
Full
Full
Auto
Auto
1. Auto
2. Full Duplex
0. Return and Apply
Figure 15: Setting up Duplex Mode
This screen will let you set the Duplex mode if the Speed setting is less that 1Gbps.
If the Speed is 1Gbps, the Duplex mode is forced to Autonegotiate.
Pressing
when on the Slot Status Screen of a Copper Bypass TAP Module, will
bring up the Reverse Bypass Mode Configuration. Reverse Bypass disables link on
both live network ports if any inline appliances lose link or cannot pass traffic. This
feature is disabled by default.
Figure 16: Setting up Reverse Bypass Mode ON or OFF
==========================
Slot 1 Reverse Bypass Mode Configuration
==========================
Current Reverse Bypass: OFF
New Reverse Bypass: OFF
1. ON
2. OFF
0. Return and Apply
M1G2ACE/M1G2DCE
M1G1ACE/M1G1DCE
M1G2ACE/M1G2DCE
M1G1ACE/M1G1DCE