Critical Requirements
SUMMARY OF OPERATIG CODITIOS
Maximum Tolerance of
Nominal Supply Voltage
+6 /-10 %
Supply frequency
50/60 Hz
Ingress Protection class
IP X0 (Protection by customer is
required.)
Minimal Diameter of
Induction Pan
5” (12cm)
Maximum Ambient
Temperature
In Storage > -4°F to +158°F
(-20°C to +70°C)
In Operation >+ 41°F to +104°F
(+5°C to +40°C)
Maximum Relative Air
Humidity
In Storage > 10% to 90%
In Operation > 30% to 90%
Clearance from Materials
Min. 40mm / 1.57”
Maximum Air Flow
70.63cfm/120m
3
per hour
Minimum opening: total sum of
10.075in
2
/6500mm
2
is required.
Network Impedance (Zmax) 0.25 Ω
LED Lamp Operation
24V DC / max. 40mA / green
Potentiometer
10 kOhm