background image

Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent 
using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been 
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation 
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, 
or which has been modified or repaired using unauthorized parts or by unauthorized service agents . 
For a list of authorized service agents, please refer to the Garland web site at http://www .garland-group .com . 

The information contained herein, (including design and parts specifications), may be superseded and is subject 

to change without notice .

GARLAND COMMERCIAL INDUSTRIES

185 East South Street

Freeland, Pennsylvania 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

GARLAND COMMERCIAL RANGES, LTD .

1177 Kamato Road, Mississauga, Ontario L4W 1X4

CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Enodis UK LTD .

Swallowfi eld Way, Hayes, Middlesex UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

Part # P143 (11/10/08)

© 2005 Garland Commercial Industries, Inc .

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE 

OR OTHER FLAMMABLE VAPORS OR 

LIQUIDS IN THE VICINITY OF 

THIS OR ANY OTHER

APPLIANCE

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, 

ALTERATION, SERVICE OR MAINTENANCE 

CAN CAUSE PROPERTY DAMAGE, INJURY, 

OR DEATH. READ THE INSTALLATION, 

OPERATING AND MAINTENANCE 

INSTRUCTIONS THOROUGHLY 

BEFORE INSTALLING OR 

SERVICING THIS EQUIPMENT

PLEASE READ ALL SECTIONS OF THIS MANUAL 

AND RETAIN FOR FUTURE REFERENCE .

THIS PRODUCT HAS BEEN CERTIFIED AS 

COMMERCIAL COOKING EQUIPMENT AND 

MUST BE INSTALLED BY PROFESSIONAL 

PERSONNEL AS SPECIFIED . 

For Your Safety:

Post in a prominent location, instructions to be 

followed in the event the user smells gas . This 

information shall be obtained by consulting 

your local gas supplier .

INSTALLATION AND 

OPERATION MANUAL

MASTER SENTRY 

GAS-OPERATED 

SALAMANDER

Summary of Contents for MSTSR16-280

Page 1: ...Phone 570 636 1000 Fax 570 636 3903 GARLAND COMMERCIAL RANGES LTD 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis U Swallowfiel Telephone Fax 081 84 Part...

Page 2: ...d expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer Operation of this prod...

Page 3: ...NTRODUCTION 6 Uncrating 6 Product Application 6 Optional Extras 6 Rating Plate 6 INSTALLATION 7 General Installation 7 Clearances 7 Siting 7 Ventilation Air 7 Statutory Regulations 7 COMMISSIONING 8 B...

Page 4: ...64 mm wide x 1089 mm high infra red restaurant range mount salamander MSTSR16 864 mm wide x 1089 mm high infra red heavy duty range mount salamander Suffix Definitions MST SRC SR16 280 SR16 SRC Counte...

Page 5: ...ominal Heat Input Gross kW BTU HR MJ HR kW BTU HR MJ HR MSTSRC 9 23 31 500 33 23 8 35 28 500 30 1 MSTSR16 9 23 31 500 33 23 8 35 28 500 30 1 Table D Setting Pressure Injector Size MODEL SECTION G20 20...

Page 6: ...Wherever possible avoid overheating idle equipment as this is the primary cause for increased service cost Regular Maintenance Ensures Peak Performance Uncrating Check crate for possible damage sustai...

Page 7: ...able of adequately supporting the weight of the appliance and any ancillary equipment Refer to table A for weight specifications Any openings in the wall behind or beside the appliance must be sealed...

Page 8: ...able it to be isolated in an emergency Wherever practical this shall be located either outside the kitchen or near to an exit in a readily accessible position Where it is not practical to do this an a...

Page 9: ...it counter clockwise to the full flame position thus lighting the main burner 5 For low flame or simmer push the tap in and turn it counter clockwise to the low flame position 6 To shut the burner off...

Page 10: ...ue may be removed with a lightweight non metallic scouring pad 4 Clean out grease drawer and wash thoroughly in hot soapy water Dry thoroughly Stainless Steel Stainless steel should be cleaned using a...

Page 11: ...g the pilot REPLACEMENT OF PARTS WARNING Turn off the gas supply to the appliance at the service cock before commencing any servicing work IMPORTANT Test for gas soundness on completion of any servici...

Page 12: ...your Garland dealer before attempting to carry out the conversion NOTE Conversion kits supplied for G31 gas will contain redundant fittings and markings covering both 37 mbar 50 mbar gas supplies 2 Re...

Page 13: ...hermocouple connection Tighten connection Faulty thermocouple Replace thermocouple Faulty flame safety device Replace flame safety device Low millivolt output on open circuit test Pilot flame too smal...

Page 14: ...Part P143 11 10 08 Page 14...

Page 15: ...Part P143 11 10 08 Page 15...

Page 16: ......

Reviews: