background image

Part # P143 (11/10/08)

Page 13

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

Burner flame too large .

Incorrect setting pressure or injector .

Check setting pressure and injector .

Burner flame soft - yellow tip .

Insufficient primary air .

Check primary aeration for blockage .

Delayed Ignition

Pilot burner flame too small .

Check pilot flame adjustment .

Burner ports blocked .

Clean blocked burner ports .

Incorrect setting pressure .

Check setting pressure .

Pilot Burner will not ignite

Pilot orifice blocked .

Clean pilot jet .

Pilot adjusting screw closed .

Open pilot adjuster .

Pilot Keeps Extinguishing .

Pilot flame too small .

Check pilot .

Loose thermocouple connection .

Tighten connection .

Faulty thermocouple .

Replace thermocouple .

Faulty flame safety device .

Replace flame safety device .

Low millivolt output on  

open circuit test .

Pilot flame too small .

Adjust pilot flame length .

Defective thermocouple .

Replace thermocouple .

Millivolt output high in open circuit test 

but low in closed circuit test .

Faulty flame safety device .

Replace flame safety tap .

Millivolt output high on closed circuit 

test but flame safety tap will not stay 

open .

Faulty flame safety device .

Replace flame safety tap .

SAFETY

It is essential that the instructions in this booklet are strictly 

followed for the safe and economical operation of the 

equipment . If it is known or suspected that a fault exists on 

the appliance then it must not be used until the fault has 

been rectified by a competent person .

Summary of Contents for MSTSR16-280

Page 1: ...Phone 570 636 1000 Fax 570 636 3903 GARLAND COMMERCIAL RANGES LTD 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis U Swallowfiel Telephone Fax 081 84 Part...

Page 2: ...d expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer Operation of this prod...

Page 3: ...NTRODUCTION 6 Uncrating 6 Product Application 6 Optional Extras 6 Rating Plate 6 INSTALLATION 7 General Installation 7 Clearances 7 Siting 7 Ventilation Air 7 Statutory Regulations 7 COMMISSIONING 8 B...

Page 4: ...64 mm wide x 1089 mm high infra red restaurant range mount salamander MSTSR16 864 mm wide x 1089 mm high infra red heavy duty range mount salamander Suffix Definitions MST SRC SR16 280 SR16 SRC Counte...

Page 5: ...ominal Heat Input Gross kW BTU HR MJ HR kW BTU HR MJ HR MSTSRC 9 23 31 500 33 23 8 35 28 500 30 1 MSTSR16 9 23 31 500 33 23 8 35 28 500 30 1 Table D Setting Pressure Injector Size MODEL SECTION G20 20...

Page 6: ...Wherever possible avoid overheating idle equipment as this is the primary cause for increased service cost Regular Maintenance Ensures Peak Performance Uncrating Check crate for possible damage sustai...

Page 7: ...able of adequately supporting the weight of the appliance and any ancillary equipment Refer to table A for weight specifications Any openings in the wall behind or beside the appliance must be sealed...

Page 8: ...able it to be isolated in an emergency Wherever practical this shall be located either outside the kitchen or near to an exit in a readily accessible position Where it is not practical to do this an a...

Page 9: ...it counter clockwise to the full flame position thus lighting the main burner 5 For low flame or simmer push the tap in and turn it counter clockwise to the low flame position 6 To shut the burner off...

Page 10: ...ue may be removed with a lightweight non metallic scouring pad 4 Clean out grease drawer and wash thoroughly in hot soapy water Dry thoroughly Stainless Steel Stainless steel should be cleaned using a...

Page 11: ...g the pilot REPLACEMENT OF PARTS WARNING Turn off the gas supply to the appliance at the service cock before commencing any servicing work IMPORTANT Test for gas soundness on completion of any servici...

Page 12: ...your Garland dealer before attempting to carry out the conversion NOTE Conversion kits supplied for G31 gas will contain redundant fittings and markings covering both 37 mbar 50 mbar gas supplies 2 Re...

Page 13: ...hermocouple connection Tighten connection Faulty thermocouple Replace thermocouple Faulty flame safety device Replace flame safety device Low millivolt output on open circuit test Pilot flame too smal...

Page 14: ...Part P143 11 10 08 Page 14...

Page 15: ...Part P143 11 10 08 Page 15...

Page 16: ......