Part # P143 (11/10/08)
Page 7
For proper operation, the Fuel information on the data plate
of you new equipment must match your fuel supply .
INSTALLATION
General Installation
1 . Carefully remove unit from carton . All packing material
must be removed from the unit . The wires for retaining
the burners & other packing material must be removed
from unit . On stainless steel units, the protective
material covering the stainless steel must be removed
immediately after unit is installed .
NOTE: Do not remove permanently affixed labels, warnings
or data plates from the appliance, for this may invalidate the
manufacturer’s warranty .
2 . Place the appliance in the required position and level by
means of the levelling feet .
3 . Connect the gas supply pipe work to the appliance . The
connection is made to the rear right hand side of the
appliance .
NOTE: A gas isolation cock must be fitted in the supply
to the appliance . The gas isolation cock must be sited in a
position which is easily accessible to the user .
Clearances
The space in which the appliance is to be sited must include
the minimum installation clearances to combustible surfaces
shown in the following table .
MINIMUM INSTALLATION CLEARANCES
Surface
All Models
Top
1219mm (48 in .)
Left Hand Side
152mm (6 in .)
Right Hand Side
152mm (6 in .)
Rear
152mm (6 in .)
TYPE OF FLOOR OR BASE
Combustible
Siting
The unit should be installed on a firm, smooth and level
base capable of adequately supporting the weight of the
appliance and any ancillary equipment . (Refer to table A for
weight specifications) . Any openings in the wall behind or
beside the appliance must be sealed . Once in position check
that the unit is level, both front to back and side to side .
Adjust if necessary using the leveling feet on the four corners
of the fitted legs .
Ventilation Air
The area in which the appliance is installed must be
adequately ventilated to provide air for combustion, removal
of products of combustion, etc . The use of a mechanical
extract system should be considered
The following notes are intended to give general guidance .
For detailed recommendations, refer to the applicable
code(s) in the Country of destination .
1: The room containing the appliance is required to have a
permanent air vent . The minimum effective area of the
vent is related to the maximum rated heat input of the
appliance and shall be 4 .5 cm
2
per kW in excess of 7 kW .
2: Air vents should be of such a size to compensate for the
effects of any extract fan in the premises .
Statutory Regulations
The installation of this appliance must be carried out by
a competent person and in accordance with the relevant
regulations, standards, codes of practice and the related
publications of the Country of destination .
AUSTRALIA SPECIFIC CLAUSE This appliance must be
installed in accordance with the manufacturers instructions,
local gas fitting regulations and requirements of AS 5601 /
AG 601 installation code . All burner adjustments and settings
should be made by a qualified gas technician .