TO REPLACE THE LINEAR ACTUATOR (continued)
4. With the weight of the
platen supported by
the object inserted
in step 3, use pliers
to work the clevis pin
retaining clip outward,
making sure to grip it
as close to the pin as
possible to prevent
deforming it.
5. Use the pliers to
remove the spring
clip from the pin at
the base of the Linear
Actuator.
6. Push the pin through
the actuator base
toward the inside of
the grill. Reach around
to the inside and
remove.
7. Remove the Linear
Actuator from the grill,
carefully pulling it out
the rear.
8. Support the weight
of the platen while
removing the pry bar.
Then, carefully lower
platen to the down
position, resting it on
the grill plate.
9. Screw NEW linear
actuator shaft down
approximately 2 turns
from bottoming out.
DO NOT completely
bottom out shaft as
it may not be long
enough to reconnect
the upper clevis clip.
10. Re-install linear
actuator into rack
assembly. If motor
does not clear the
cross member, use pry
bar to gently lift and
fit as previously done
in step 3. Reinstall
actuator base pin from
inside and remount its
spring clip.
11. Gently fit clevis
clip through top of
actuator shaft and
cross member bar. Use
pry bar to align holes.
12. Reconnect wires as
shows in the photos to
the right.