OPERATOR TROUBLESHOOTING Continued
Problem
Probable Causes
Corrective Action
BURNERS DO NOT LIGHT
(Main gas supply valve verified to be
open, the gas valve is verified to be ON,
and power switch is verified to be ON.)
A. Ignition module lockout (the
burners failed to light within 4
seconds).
Indicator: Red trouble light on
control panel is illuminated.
A. Turn the controller OFF. Open the
control panel by removing the
screws in the upper corners. If there
are two ignition modules, check for
blown 2-amp fuses and replace as
necessary. Close the control panel
and press the power switch. Wait at
least 4 minutes.
B. Dirty water level sensors. (If the
computer does not sense sufficient
water in the cookpot, it will not
allow the burners to fire.)
B. Remove the probe block cover
and clean the sensors using a
Scotchbrite™ or similar pad and a
solution of detergent and water.
NOTE
: Do not use deliming solution.
C. Failed controller.
C. Order replacement controller from
FASC or distributor.
D. Failed ignition module or gas valve,
or broken or loose wiring
C. Call FASC.
ON UNIT WITH AUTOFILL, COOKPOT
DID NOT FILL WHEN UNIT WAS
TURNED ON
(Water supply to unit verified to be ON.)
A. Dirty water level sensors.
A. Remove the probe block cover
and clean the sensors using a
Scotchbrite™ or similar pad and a
solution of detergent and water.
NOTE
: Do not use deliming solution.
B. Failed controller.
B. Order replacement controller from
FASC or distributor.
C. Shorted upper water level sensor,
failed water solenoid valve, or loose/
broken wiring.
C. Call FASC.
Operator Troubeshooting Guides
Summary of Contents for PASTA MAGIC
Page 17: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 17 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 21: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 21 Notes...
Page 22: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 22 Notes...
Page 23: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 23 THIS PAGE INTENTIONALLY LEFT BLANK...