INSTALLATION INSTRUCTIONS Continued

being supplied before connecting the quick-disconnect 

device or piping from the gas supply line.  

9.  Refer to the table below to verify the minimum and 

maximum gas supply pressures for the type of gas being 

used.

Standard for Incoming Gas Pressures

Gas

Minimum

Maximum

Natural

6.0” WC

1.62 kPa

16.19 mbar

14” WC

3.48 kPa

34.87 mbar

Propane

11” WC

2.74 kPa

27.37 mbar

14” WC

3.48 kPa

34.87 mbar

Connection to Gas Line

The Pasta Magic family of gas cookers has been approved for 

use with natural and propane (LP) gas.  

The size of the gas line used for installation is very important.  

If the line is too small, the gas pressure at the burner 

manifold will be low.  This may cause slow recovery and 

delayed ignition.  Garland recommends the incoming gas 

supply line be a minimum of 1 ½” (38mm) in diameter.  Refer 

to the chart below for the minimum sizes of connection 

piping.

Gas Connection Pipe Sizes

(Minimum incoming pipe size should be 1½” (38 mm))

Gas

Single Unit

2-3 Units

Natural

¾” (19 mm)

1” (25 mm)

Propane

½” (13 mm)

¾” (19 mm)

 

Note:

 For distances of more than 20 feet (6m) and/or 

more than four fittingsor elbows, increase the connection 

by one pipe size.

Before connecting new pipe to your unit, the pipe must be 

thoroughly blown out to remove any foreign particles.  If 

these foreign particles get into the burner and controls, they 

will cause improper and sometimes dangerous operation.

1.  Connect the quick-disconnect hose to the cooker quick-

disconnect fitting at the rear of the cooker and to the 

building gas line.

 

NOTE:

 Some cookers are configured for a rigid 

connection to the gas supply line.  These units must 

be connected to the gas supply line at the rear of the 

unit using fittings approved for that purpose by the 

appropriate regulatory agency of the country in which 

the appliance is installed.

4.  For units equipped with basket lifts, install the basket lift 

arms onto the rods (located at the top rear of the cabinet) 

to ensure that the lift arms are guided by the basket lift 

rollers.

5.  Connect the water supply to the faucet and, on units with 

the autofill option, the water solenoid valve.  (The valve is 

located on the lower frame behind the doorpost.)

,

CAUTION

Before connecting the water supply to units equipped 

with solenoid valves, purge the water line to ensure 

there is no trash in the line.

 DANGER

The maximum allowable incoming water pressure to the 

regulator for all units is 80 PSI (56.3 kg/cm2).
The maximum allowable incoming water temperature 

for all units is 180°F (82°C).

 

NOTE:

  Either hot or cold water supplies may be 

connected to the water solenoid valve.  However, 

connecting to a hot water supply will minimize the 

amount of time required to attain operating temperature 

when filling the cooker with fresh water.  

 

NOTE:

  In order for the water level sensors to work 

properly, a certain amount of mineral content is 

necessary in the water.  For that reason, purified, 

deionized, or highly filtered water should not be used.

6.  Connect the desired drain plumbing to the 1¼–inch 

drain valve.  NOTE: Ensure drain plumbing is connected 

in accordance with local codes. Waste water from the 

water bath unit should not be discharged directly below 

the appliance. Rising steam can harm the cabinet and the 

electrical components.

7.  Test the cooker electrical system:

a.  Plug the cooker electrical cord into a grounded 

electrical receptacle of appropriate voltage.  (Check 

the rating plate on the cooker door to determine the 

proper voltage).

b.  Place the power switch in the 

ON

 position and verify 

that the display indicates

 

LO

.

c.  Place the cooker power switch in the 

OFF

 position. 

Verify that the display is blank.

8.  Refer to the rating plate on the inside of the cooker door 

to verify that the cooker is configured for the type of gas 

Summary of Contents for PASTA MAGIC

Page 1: ...nd web site at http www garland group com The information contained herein including design and parts specifications may be superseded and is subject to change without notice WARNING IMPROPER INSTALLA...

Page 2: ...BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL INC BOCA AND THE FOOD SERVICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION GARLAND PASTA COOKERS EQUIPPED WITH LEGS ARE FOR PERMANENT...

Page 3: ...eparations 7 Connection to Gas Line 8 Converting to Another Gas Type 9 Operating Instructions 10 Finding Your Way Around the Pasta Cooker 10 Controller 11 Operating Instructions 12 Start up Procedure...

Page 4: ...n addition to the model number serial number and type of gas please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your...

Page 5: ...gas fired appliances Qualified personnel must be experienced in such work be familiar with all gas precautions involved and have complied with all requirements of applicable national and local codes...

Page 6: ...s defined in Section 1 5 of this manual should perform all installation and service on Garland equipment Conversion of this appliance from one type of gas to another should only be performed by qualif...

Page 7: ...cooker door Connect a cooker only to the type of gas indicated on the rating plate Installation shall be made with a gas connector that complies with the national and local codes or regulations in fo...

Page 8: ...egulatory agency of the country in which the appliance is installed 4 For units equipped with basket lifts install the basket lift arms onto the rods located at the top rear of the cabinet to ensure t...

Page 9: ...ng to Another GasType DANGER Your cooker is configured at the factory for a specific type of gas If you desire to switch from one type of gas to another specific gas conversion components must be inst...

Page 10: ..._PASTACUISINE_4607873 08 21 10 OPERATING INSTRUCTIONS FindingYourWay Around the Pasta Cooker Overflow Low water sensor High water sensor Temp probe Drain Cook pot Trouble light Controller Drain valve...

Page 11: ...ces the efficiency of the cooker and can cause erroneous temperature and water level sensing NOTE Do not use deliming solution to clean these units Use of deliming solution will damage all stainless s...

Page 12: ...hould display a bright orange red glow If a blue flame is observed or if there are dark spots on a burner face the air gas mixture requires adjustment as explained below NOTE Adjusting the Air Gas Mix...

Page 13: ...r turn the unit off and add cold water until the solution is cool Drain the solution and clean the cookpot thoroughly with a solution of dishwashing detergent and hot water 5 Rinse the cookpot at leas...

Page 14: ...water and or food products Clean Water Level Sensors Temperature Probe Cookpot and Rinse Tank 1 Turn the equipment off and drain the cookpot and rinse tank if so equipped 2 Remove the probe cover and...

Page 15: ...display a bright orange red glow If a blue flame is observed or if there are dark spots on a burner face the air gas mixture requires ad justment On the side of the blower housing opposite the motor...

Page 16: ...sing wire was removed 3 Place the power switch in the ON position to light the burners After the cookpot temperature reaches 2000F 930C wait at least one minute before checking the reading NOTE The cl...

Page 17: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 18: ...the Welbilt KitchenCare HOTLINE 844 724 2273 Verify that electrical cords are plugged in and that circuit breakers are on Verify that water supply valves are open and that the drain valves are fully c...

Page 19: ...es not sense sufficient water in the cookpot it will not allow the burners to fire B Remove the probe block cover and clean the sensors using a Scotchbrite or similar pad and a solution of detergent a...

Page 20: ...oller If the AUTOFILL functions correctly the only cause possible is a failed controller A Order replacement controller from FASC or distributor WATER WILL NOT BOIL Cookpot verified to be full of wate...