NOTE:
When using thread compound, use very small
amounts on male threads only. Use a pipe thread
compound that is not affected by the chemical action of
LP gases (i.e. propane, G31) (Loctite™ PST56765 Sealant is
one such compound). DO NOT apply compound to the
first two threads. This will ensure that the burner orifices
and control valve do not become clogged.
2. Open the gas supply to the cooker and check all piping,
fittings, and gas connections for leaks. A soap solution
should be used for this purpose.
DANGER
Never use matches, candles, or any other ignition source
to check for leaks. If gas odors are detected, shut off the
gas supply to the cooker at the main shut-off valve and
contact the local gas company or an authorized service
agency for service.
3. Close the cooker drain valve and fill the cookpot with
water and detergent. Light the cooker and perform the
boil-out procedures that are described in the “Boiling Out
the Cookpot” section.
n
WARNING
“Dry-firing” this equipment will cause damage to the
cookpot. Always ensure that water is in the cookpot
before firing your unit.
4. It is recommended that the burner gas pressure be
checked at this time by the local gas company or an
authorized service agent. Refer to “Adjusting the Burner
Gas Pressure” section of this manual for the proper
procedure. The accompanying tables list the burner gas
pressures for the various gas types that can be used with
this equipment.
Standard for Incoming Gas Pressures
Gas
Pressure
Natural
3” WC
.87 kPa
8.718 mbar
Propane
8.25” WC
2.054 kPa
20.55 mbar
Converting to Another Gas Type
DANGER
Your cooker is configured at the factory for a specific
type of gas. If you desire to switch from one type of gas
to another, specific gas-conversion components must be
installed.
Switching to a different type of gas without installing
the proper conversion components may result in fire or
explosion! NEVER attach your cooker to a gas supply for
which it is not configured.
Conversion of this appliance from one type of gas to
another should only be performed by qualified, licensed,
and/or authorized installation or service personnel, as
defined in section - Installation, Operating and Service
Personnel.
Gas Conversion Components
Natural Gas to LP (Propane)
Gas:
LP (Propane) Gas to Natural
Gas:
Orifice
: 810-0386 (2
required)
Ignitor Kit
: 826-0982 (2
required)
Regulator
: 807-1848 (1
required)
Conversion Rating Label
802-2144
.
Orifice
: 810-0403 (2 required)
Ignitor Kit
: 826-0981 (2 required)
Regulator
: 807-1847 (1 required)
Conversion Rating Label 802-
2144 .
Gas Conversion Instructions
1. Change the orifices.
2. Change the ignitors.
3. Install the regulator kit in the gas valve in accordance
with the instructions furnished with the kit.
4. Adjust the incoming gas pressure for the new gas. (Refer to
the
Standard for Incoming Gas Pressures
table on this page.)
5. Adjust the gas pressure at the gas valve regulator. (Refer
to the
Standard for Burner Gas Pressures
table on this page
and section - Adjusting the Burner Gas Pressure. )
6. Affix the new label included with the conversion kit
next to the existing rating plate stating that the gas
type has been converted. Remove any references to the
previously used gas from the existing rating plate. Label
PN 802-2144.
7. If the destination language changes, replace the labels.
(You must contact your local service agency. The
language of reference is indicated on the corner of the
label.)
Summary of Contents for PASTA MAGIC
Page 17: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 17 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 21: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 21 Notes...
Page 22: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 22 Notes...
Page 23: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 23 THIS PAGE INTENTIONALLY LEFT BLANK...