background image

Part # P152 Rev 1 (01/13/10)

Page 1

Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent 
using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been 
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation 
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, 
or which has been modified or repaired using unauthorized parts or by unauthorized service agents . 
For a list of authorized service agents, please refer to the Garland web site at http://www .garland-group .com . 

The information contained herein, (including design and parts specifications), may be superseded and is subject 

to change without notice .

GARLAND COMMERCIAL INDUSTRIES, LLC

185 East South Street

Freeland, Pennsylvania 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

GARLAND COMMERCIAL RANGES, LTD .

1177 Kamato Road, Mississauga, Ontario L4W 1X4

CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Part # P152 Rev 1 (01/13/10)

© 2004 Garland Commercial Industries, LLC

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE 

OR OTHER FLAMMABLE VAPORS OR 

LIQUIDS IN THE VICINITY OF 

THIS OR ANY OTHER

APPLIANCE

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, 

ALTERATION, SERVICE OR MAINTENANCE 

CAN CAUSE PROPERTY DAMAGE, INJURY, 

OR DEATH. READ THE INSTALLATION, 

OPERATING AND MAINTENANCE 

INSTRUCTIONS THOROUGHLY 

BEFORE INSTALLING OR 

SERVICING THIS EQUIPMENT

INSTALLATION AND 

SERVICE MANUAL

GARLAND S680, SS680 & 

SU680 SERIES RESTAURANT 

RANGES AND SALAMANDERS

PLEASE READ ALL SECTIONS OF THIS MANUAL 

AND RETAIN FOR FUTURE REFERENCE .

THIS PRODUCT HAS BEEN CERTIFIED AS 

COMMERCIAL COOKING EQUIPMENT AND 

MUST BE INSTALLED BY PROFESSIONAL 

PERSONNEL AS SPECIFIED . 

INSTALLATION AND ELECTRICAL CONNECTION 

MUST COMPLY WITH CURRENT CODES:

IN CANADA - THE CANADIAN ELECTRICAL 

CODE PART 1 AND / OR LOCAL CODES .

IN USA – THE NATIONAL ELECTRICAL CODE 

ANSI / NFPA – CURRENT EDITION .

ENSURE ELECTRICAL SUPPLY CONFORMS WITH 

ELECTRICAL CHARACTERISTICS SHOWN ON 

THE RATING PLATE .

Summary of Contents for S680 SERIES

Page 1: ...903 GARLAND COMMERCIAL RANGES LTD 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Part P152 Rev 1 01 13 10 2004 Garland Commercial Industries LLC FOR YOUR SAFET...

Page 2: ...tate of California to cause cancer and or birth defects or other reproductive harm Installation and servicing of this product could expose you to airborne particles of glass wool ceramic fibers Inhala...

Page 3: ...Assembly of Backguard High Shelf 10 Code Requirements 10 Electrical Supply 10 Single And Three Phase Connection 10 Commissioning 10 Thermostat Calibration 11 REPLACEMENT OF PARTS 12 Door Switch 12 Fan...

Page 4: ...imensions Oven Interior Dimensions Height Width Depth Height Width Depth 47 1194mm 60 1524mm 34 1 4 870mm 13 1 2 343mm 26 1 4 667mm 22 559mm With Front Rail Note Shipping Cubic Feet is 84 5 Ratings Tu...

Page 5: ...pth 47 1194mm 36 914mm 34 1 4 870mm 13 1 2 343mm 26 1 4 667mm 22 559mm With front rail Note Shipping Cubic Feet is 58 5 Entry Clearances Crated Uncrated Uncrated RC Model 45 1143mm 35 889mm 40 1016mm...

Page 6: ...12 305mm wide solid top 2 24 610mm wide solid top 3 36 915mm wide solid top L Solid top on left hand side of range C Solid top in center of range R Solid top on right hand side of range RC Convection...

Page 7: ...V 3 Ph 240V 1Ph 240V 3 Ph 400 V 3N 415V 3N SERC SER 680 wired independently 7 34 29 29 25 15 15 Installation Notes Clearances from combustible surfaces should be minimum 7 178mm from sides 2 51mm from...

Page 8: ...del number including the prefix and suffix letters and numbers and the warranty serial number The rating plate affixed to the unit contains this information Safety Precautions This manual pertains to...

Page 9: ...specifications for weights Place the range or salamander in desired position and level from side to side and back to front and diagonally This leveling must be done with the unit under the hood and i...

Page 10: ...upply electrical characteristics agree On ranges and salamanders the supply entrance is located at the rear or alternatively on the main bottom The supply terminal block is accessible from the front T...

Page 11: ...rature NOTE each turn of the screw will create a change of approximately 35 F 20 C 6 Replace the thermostat dial and repeat steps 1 though 3 to verify that the correct adjustment has been made Dial Sh...

Page 12: ...ets and remove screws securing the door switch 3 Remove the terminal cover and disconnect the wires from the terminals on the body of the switch 4 Replace the faulty door switch 5 Make certain that th...

Page 13: ...acent griddle is operating at a different temperature Check adjacent griddle section Griddle was not thoroughly heated before using Allow more time for griddle to saturate Increase warm up time HotTop...

Page 14: ...k Position Motor working thermostat set to temperature lamp on oven not heating Relay RL1 is defective Replace relay Defective heating element or wiring Replace heating element or repair wiring Noisy...

Page 15: ...Part P152 Rev 1 01 13 10 Page 15 APPENDIX Wiring Diagrams and Loading Charts...

Page 16: ...SHT OF CHK BY REV REV DATE DR DESCRIPTION REVISIONS 3350W TOPS 20A 4600W TOPS 30A 12 N BLACK L1 RED L1 H2 L2 H1 P L1 H2 L2 H1 P 3 35kW TOTAL 8 2 1kW 6 1 25kW HOT TOP OPEN TOP 30A _0A _0A _0A 40A SALA...

Page 17: ...odels 1C 12R 24R 2R GROUP 1 WITH SALMANDER 3 PHASE X T3 1 O1 1 T2 1 T1 1 TOP 3 RED OVEN 1 RED TOP 2 RED TOP 1 RED O1 1 G Z Y T2 2 T1 2 O1 2 T3 2 SS686 Models 1C 12R 24R 2R GROUP 1 NO SALMANDER 3 PHASE...

Page 18: ...60 4 85 47 32 48 29 39 35 77 64 X Y Top 3 16 15 240 6 70 4 60 4 85 41 01 41 86 34 10 67 29 Y Z Oven WITH SALAMANDER domestic delta load Total kW voltage kW X Z kW X Y kW Y Z A X A Y A Z A 1 phase X Z...

Page 19: ...MISSISSAUGA ONTARIO CANADA TITLE DATE SCALE DR SHT OF CHK BY REV REV DATE DR DESCRIPTION REVISIONS 3350W TOPS 20A 4600W TOPS 30A 12 N BLACK L1 RED L1 H2 L2 H1 P L1 H2 L2 H1 P 3 35kW TOTAL 8 2 1kW 6 1...

Page 20: ...OP 2 RED TOP 3 RED OVEN 1 RED TOP 2 BLACK TOP 3 BLACK TOP 1 BLACK TOP 1 RED SALAMANDER BLACK OVEN 1 BLACK SALAMANDER RED SU686 Models 1C 12R 24R 2R O1 2 T2 2 T3 2 T1 2 S 2 O1 1 T2 1 T3 1 S 1 T1 1 E N...

Page 21: ...70 22 L2 Top 3 415V 3N 16 15 6 7 4 6 4 85 27 92 19 17 20 21 67 29 L3 Oven 380V 3N 14 78 6 13 4 21 4 44 27 86 19 13 20 17 67 16 WITH SALAMANDER export wye load voltage total kW kW L1 kW L2 kW L3 A L1 A...

Page 22: ...R DESCRIPTION REVISIONS 3350W TOPS 20A 4600W TOPS 30A 12 TOP RL2 RL1 N BLACK L1 RED L1 H2 L2 H1 P L1 H2 L2 H1 P 3 35kW TOTAL 8 2 1kW 6 1 25kW HOT TOP OPEN TOP 40A _0A _0A _0A 40A SALAMANDER BLACK OVEN...

Page 23: ...RC Models 12R 1L 12R 1R 1R 12L 24L SS686RC Models 12R 1L 12R 1R 1R 12L 24L SS686RC Models 1C 12R 24R 2R SS686RC Models 1C 12R 24R 2R O1 2 OVEN 1 BLACK OVEN 1 BLACK T2 2 T1 2 T3 2 O1 2 TOP 2 BLACK TOP...

Page 24: ...ION THE DOOR MUST BE CLOSED THERMOSTAT CLOSED BEFORE THE OVEN HEATING ELEMENTS ARE ENERGIZED COOL POSITION THE FAN SWITCH MUST BE IN THE COOL POSITION THE DOOR MUST BE OPEN THE FAN WILL OPERATE BUT TH...

Page 25: ...4 60 5 50 47 32 50 88 42 11 80 77 X Y Top 3 16 80 240 6 70 4 60 5 50 41 01 44 09 36 49 70 00 Y Z Oven WITH SALAMANDER domestic delta load Total kW voltage kW X Z kW X Y kW Y Z A X A Y A Z A 1 phase X...

Page 26: ...ITLE DATE SCALE DR SHT OF CHK BY REV REV DATE DR DESCRIPTION REVISIONS 3350W TOPS 20A 4600W TOPS 30A 12 TOP RL2 RL1 N BLACK L1 RED L1 H2 L2 H1 P L1 H2 L2 H1 P 3 35kW TOTAL 8 2 1kW 6 1 25kW HOT TOP OPE...

Page 27: ...L2 3 PHASE L1 E N L3 L2 3 PHASE L1 SU686RC Models 12R 1L 12R 1R 1R 12L 24L E N L3 L2 3 PHASE L1 OVEN 1 BLACK T3 1 TOP 3 RED T1 2 T3 2 T2 2 O1 2 O1 1 TOP 1 BLACK TOP 3 BLACK TOP 2 BLACK OVEN 1 RED T2...

Page 28: ...TION THE DOOR MUST BE CLOSED THERMOSTAT CLOSED BEFORE THE OVEN HEATING ELEMENTS ARE ENERGIZED COOL POSITION THE FAN SWITCH MUST BE IN THE COOL POSITION THE DOOR MUST BE OPEN THE FAN WILL OPERATE BUT T...

Page 29: ...op 3 415V 3N 16 8 6 7 4 6 5 50 27 92 19 17 22 92 70 00 L3 Oven 380V 3N 15 37 6 13 4 21 5 03 27 86 19 13 22 87 69 87 WITH SALAMANDER export wye load voltage total kW kW L1 kW L2 kW L3 A L1 A L2 A L3 A...

Page 30: ...P L1 H2 L2 H1 P 3 35kW TOTAL 8 2 1kW 6 1 25kW HOT TOP OPEN TOP 30A _0A _0A 30A _0A _0A _0A 40A TOP 5 BLACK TOP 4 BLACK OVEN 2 BLACK SALAMANDER BLACK OVEN 1 BLACK TOP 3 BLACK TOP 2 BLACK TOP 1 BLACK TO...

Page 31: ...NDER 3 PHASE X T1 1 T3 1 T4 1 O1 1 T2 1 T5 1 SS684 Models 1L 24R 24R 2R 2R 12L 2R 24L SS684 Models 12R 1L 12R 1R 1R 12L OVEN 1 RED TOP 5 RED TOP 1 RED TOP 2 RED TOP 3 RED TOP 4 RED TOP 1 BLACK TOP 2 B...

Page 32: ...2 TOP 4 BLACK OVEN 1 BLACK TOP 5 BLACK T4 2 O1 2 T5 2 S 2 OVEN 2 RED TOP 4 RED TOP 1 BLACK OVEN 2 BLACK TOP 2 BLACK SALAMANDER RED T1 2 T2 2 O2 2 T4 1 S 1 GROUP 7 WITH SALMANDER 3 PHASE OVEN 1 RED TO...

Page 33: ...Part P152 Rev 1 01 13 10 Page 33...

Page 34: ...9 45 86 52 86 51 78 69 145 19 X Y Top 4 Oven 1 30 20 240 11 3 9 45 9 45 74 77 74 97 68 20 125 83 Y Z Oven 2 Top 5 WITH SALAMANDER domestic delta load Total kW voltage kW X Z kW X Y kW Y Z A X A Y A Z...

Page 35: ...20 9 45 76 12 61 20 73 55 133 17 X Y Top 1 Oven 1 27 70 240 10 05 8 20 9 45 66 97 70 38 63 74 115 42 Y Z Oven 2 Top 2 WITH SALAMANDER domestic delta load Total kW voltage kW X Z kW X Y kW Y Z A X A Y...

Page 36: ...R DESCRIPTION REVISIONS 3350W TOPS 20A 4600W TOPS 30A 12 N BLACK L1 RED L1 H2 L2 H1 P L1 H2 L2 H1 P 3 35kW TOTAL 8 2 1kW 6 1 25kW HOT TOP OPEN TOP TOP 5 BLACK TOP 4 BLACK OVEN 2 BLACK SALAMANDER BLACK...

Page 37: ...RED TOP 4 RED TOP 2 RED TOP 1 RED OVEN 1 RED TOP 5 RED SALAMANDER BLACK OVEN 1 BLACK SALAMANDER RED OVEN 2 BLACK TOP 1 BLACK TOP 3 BLACK TOP 3 RED TOP 2 BLACK TOP 4 BLACK OVEN 2 RED S 1 T1 2 O2 2 O1 2...

Page 38: ...2 3 PHASE L1 O2 1 SU684 Models 1C 12R T3 2 O2 2 T5 2 T4 2 O1 2 T1 2 T2 2 GROUP 5 NO SALMANDER T5 1 O1 1 T2 1 T4 1 T1 1 T3 1 E N L3 L2 3 PHASE L1 GROUP 7 WITH SALMANDER SU684 Models 1C 12R 2C 12R 3L 12...

Page 39: ...Part P152 Rev 1 01 13 10 Page 39...

Page 40: ...37 2 11 55 14 05 11 6 48 13 58 54 48 33 155 00 L3 Top 5 Salamander 380V 3N 34 04 10 57 12 85 10 61 48 03 58 43 48 24 154 71 SU684 1C 12L NO SALAMANDER export wye load voltage total kW kW L1 kW L2 kW...

Page 41: ...5V 3N 34 7 11 55 11 55 11 6 48 13 48 13 48 33 144 58 L3 Top 5 Salamander 380V 3N 31 75 10 57 10 57 10 61 48 03 48 03 48 24 144 31 SU684 1L 36R SU684 3R 12L NO SALAMANDER export wye load voltage total...

Page 42: ...2 H1 P 3 35kW TOTAL 8 2 1kW 6 1 25kW HOT TOP OPEN TOP 30A _0A _0A 40A _0A _0A _0A 40A TOP 5 BLACK TOP 4 BLACK OVEN 2 BLACK SALAMANDER BLACK OVEN 1 BLACK TOP 3 BLACK TOP 2 BLACK TOP 1 BLACK TOP 5 RED T...

Page 43: ...OP 2 RED TOP 5 RED TOP 1 RED 3 PHASE SALAMANDER RED SALAMANDER BLACK OVEN 2 RED O2 1 T5 1 T4 2 S 2 T3 2 T1 2 O1 2 T5 2 O2 2 T2 2 S 1 TOP 3 BLACK OVEN 1 BLACK TOP 5 BLACK TOP 5 RED TOP 1 BLACK TOP 2 BL...

Page 44: ...OP 2 BLACK OVEN 2 BLACK TOP 1 BLACK TOP 3 BLACK OVEN 1 BLACK TOP 4 BLACK TOP 3 RED TOP 2 RED TOP 5 RED OVEN 1 RED TOP 4 RED OVEN 2 RED GROUP 7 WITH SALMANDER T1 1 G Z 3 PHASE X Y T2 2 T4 2 T3 2 O2 2 T...

Page 45: ...T OF CHK BY REV REV DATE DR DESCRIPTION REVISIONS RL2 OVEN THERMOSTAT DOOR SWITCH L 40A FAN SWITCH M N COM FAN INTERLOCK CIRCUIT OPERATION HEAT POSITION THE FAN SWITCH MUST BE IN THE HEAT POSTION THE...

Page 46: ...05 11 6 109 38 99 10 106 96 181 97 X Y Top 2 Top 4 Oven 2 37 85 240 12 2 14 05 11 6 94 80 85 89 92 70 157 71 Y Z Top 5 Salamander SS684RC 2L SS684RC 24L NO SALAMANDER domestic delta load Total kW volt...

Page 47: ...69 95 X Y Top 3 Top 4 Oven 2 35 35 240 12 20 11 55 11 60 85 71 85 89 83 54 147 29 Y Z Top 5 Salamander SS684RC 3R 12L SS684RC 1L 36R NO SALAMANDER domestic delta load Total kW voltage kW X Z kW X Y kW...

Page 48: ...NS 3350W TOPS 20A 4600W TOPS 30A 12 TOP RL2 RL1 N BLACK L1 RED L1 H2 L2 H1 P L1 H2 L2 H1 P 3 35kW TOTAL 8 2 1kW 6 1 25kW HOT TOP OPEN TOP TOP 5 BLACK TOP 4 BLACK OVEN 2 BLACK SALAMANDER BLACK OVEN 1 B...

Page 49: ...RED TOP 4 RED TOP 2 RED TOP 1 RED OVEN 1 RED TOP 5 RED SALAMANDER BLACK OVEN 1 BLACK SALAMANDER RED OVEN 2 BLACK TOP 1 BLACK TOP 3 BLACK TOP 3 RED TOP 2 BLACK TOP 4 BLACK OVEN 2 RED S 1 T1 2 O2 2 O1...

Page 50: ...3 PHASE L1 O2 1 SU684RC Models 1C 12R T3 2 O2 2 T5 2 T4 2 O1 2 T1 2 T2 2 GROUP 5 NO SALMANDER T5 1 O1 1 T2 1 T4 1 T1 1 T3 1 E N L3 L2 3 PHASE L1 GROUP 7 WITH SALMANDER SU684RC Models 1C 12R 2C 12R 3L...

Page 51: ...SHT OF CHK BY REV REV DATE DR DESCRIPTION REVISIONS RL2 OVEN THERMOSTAT DOOR SWITCH L 40A FAN SWITCH M N COM FAN INTERLOCK CIRCUIT OPERATION HEAT POSITION THE FAN SWITCH MUST BE IN THE HEAT POSTION TH...

Page 52: ...2 14 05 11 6 50 83 58 54 48 33 157 71 L3 Top 5 Salamander 380V3N 34 63 11 16 12 85 10 61 50 74 58 43 48 24 157 41 SU684RC 1C 12L NO SALAMANDER export wye load voltage total kW kW L1 kW L2 kW L3 A L1 A...

Page 53: ...1 55 11 6 50 83 48 13 48 33 147 29 L3 Top 5 Salamander 380V3N 32 34 11 16 10 57 10 61 50 74 48 03 48 24 147 01 SU684RC 1L 36R SU684 3R 12L NO SALAMANDER export wye load voltage total kW kW L1 kW L2 kW...

Page 54: ...OFF COOL TOP SWITCH RL2 RL1 40A _0A _0A 40A _0A _0A _0A 40A BLACK RED DOOR SWITCH LEFT COM 0 NC 1 2 NO T1 1 T2 1 T3 1 O1 1 S 1 O2 1 T4 1 T5 1 T1 2 T2 2 T3 2 O1 2 S 2 O2 2 T4 2 T5 2 T1 3 T1 4 T2 3 O1 3...

Page 55: ...2 RED TOP 5 RED TOP 1 RED 3 PHASE SALAMANDER RED SALAMANDER BLACK OVEN 2 RED O2 1 T5 1 T4 2 S 2 T3 2 T1 2 O1 2 T5 2 O2 2 T2 2 S 1 TOP 3 BLACK OVEN 1 BLACK TOP 5 BLACK TOP 5 RED TOP 1 BLACK TOP 2 BLACK...

Page 56: ...BLACK OVEN 2 BLACK TOP 1 BLACK TOP 3 BLACK OVEN 1 BLACK TOP 4 BLACK TOP 3 RED TOP 2 RED TOP 5 RED OVEN 1 RED TOP 4 RED OVEN 2 RED GROUP 7 WITH SALMANDER T1 1 G Z 3 PHASE X Y T2 2 T4 2 T3 2 O2 2 T1 2...

Page 57: ...BEFORE THE OVEN HEATING ELEMENTS ARE ENERGIZED COOL POSITION THE FAN SWITCH MUST BE IN THE COOL POSITION THE DOOR MUST BE OPEN THE FAN WILL OPERATE BUT THE HEATING ELEMENTS WILL NOT ENERGIZE 5kW RL1 R...

Page 58: ...14 70 11 60 112 16 99 10 109 76 185 10 X Y Top 3 Top 4 Oven 2 38 50 240 12 20 14 70 11 60 97 21 85 89 95 12 160 42 Y Z Top 5 Salamander SS864RC2 1C 12L NO SALAMANDER domestic delta load Total kW volta...

Page 59: ...X Y Top 3 Top 4 Oven 2 36 00 240 12 20 12 20 11 60 88 05 85 89 85 89 150 00 Y Z Top 5 Salamander SS684RC2 3R 12L SS684RC2 1L 36R NO SALAMANDER domestic delta load Total kW voltage kW X Z kW X Y kW Y Z...

Page 60: ...kW 6 1 25kW HOT TOP OPEN TOP DOOR SWITCH RIGHT NO 1 2 COM 0 NC 5kW TOTAL OVEN COOK OFF COOL TOP SWITCH RL2 RL1 TOP 5 BLACK TOP 4 BLACK OVEN 2 BLACK SALAMANDER BLACK OVEN 1 BLACK TOP 3 BLACK TOP 2 BLAC...

Page 61: ...S 2 T3 2 T1 2 O1 2 T5 2 O2 2 T2 2 S 1 TOP 3 BLACK OVEN 1 BLACK TOP 5 BLACK TOP 5 RED TOP 1 BLACK TOP 2 BLACK OVEN 2 BLACK TOP 4 BLACK GROUP 3 WITH SALMANDER O1 1 T4 1 T3 1 T2 1 T1 1 OVEN 1 RED TOP 4...

Page 62: ...RED TOP 4 RED OVEN 2 RED GROUP 7 WITH SALMANDER T1 1 T2 2 T4 2 T3 2 O2 2 T1 2 O1 2 O1 1 T4 1 O2 1 T5 1 T3 1 T2 1 GROUP 7 NO SALMANDER GROUP 8 WITH SALMANDER TOP 1 RED TOP 1 BLACK TOP 4 BLACK TOP 3 BLA...

Page 63: ...DESCRIPTION REVISIONS FAN INTERLOCK CIRCUIT OPERATION HEAT POSITION THE FAN SWITCH MUST BE IN THE HEAT POSTION THE DOOR MUST BE CLOSED THERMOSTAT CLOSED BEFORE THE OVEN HEATING ELEMENTS ARE ENERGIZED...

Page 64: ...12 2 14 7 11 6 50 83 61 25 48 33 160 42 L3 Top 5 Salamander 380V 3N 35 22 11 16 13 45 10 61 50 74 61 13 48 24 160 11 SU684RC2 1C 12L NO SALAMANDER export wye load voltage total kW kW L1 kW L2 kW L3 A...

Page 65: ...Top 4 Oven 2 415V 3N 36 12 2 12 2 11 6 50 83 50 83 48 33 150 00 L3 Top 5 Salamander 380V 3N 32 94 11 16 11 16 10 61 50 74 50 74 48 24 149 72 SU684RC2 1L 36R SU684 3R 12L NO SALAMANDER export wye load...

Page 66: ...VAC MODEL COMMERCIAL RANGES LIMITED MISSISSAUGA ONTARIO CANADA 3 HEAT SWITCH 2 1 4 3 P3 P1 P2 3 HEAT SWITCH 2 1 4 3 P3 P1 P2 SERC SER 680 2693600 1 DWG G Z Y X 3 PHASE 1 PHASE X Z Y 1 3 2 4 4 2 3 1 4...

Page 67: ...12 10 WP13022FT INSUL F146 TERMINAL RING 10 STUD 12 10GA 650F 7 12 H20 16 GA TGS RED STRANDED 27 1 F151 WIRE PIN 16 14WP 13015SFT F148 TERMINAL 10 RING 16 14GA OPEN BA 8 9 14 H140 16 GA SEW 1 BLACK S...

Page 68: ...V 3N MODEL COMMERCIAL RANGES LIMITED MISSISSAUGA ONTARIO CANADA 3 HEAT SWITCH 2 1 4 3 P3 P1 P2 3 HEAT SWITCH 2 1 4 3 P3 P1 P2 S U ERC S U ER 680 2693700 DWG E N L2 L1 3 PHASE 1 PHASE L1 N 1 3 2 4 4 2...

Page 69: ...ING 16 14GA OPEN BA F146 TERMINAL 10 RING 16 14GA OPEN BA 6 11 H36 12 GA TGS BLACK STRANDED 27 1 F150 WIRE PIN 12 10 WP13022FT INSUL F146 TERMINAL RING 10 STUD 12 10GA 650F 7 12 H20 16 GA TGS RED STRA...

Page 70: ...Part P152 Rev 1 01 13 10 Page 70...

Page 71: ...Part P152 Rev 1 01 13 10 Page 71...

Page 72: ......

Reviews: