Part # P152 Rev 1 (01/13/10)
Page 41
MODEL
NO SALAMANDER
Phase Grouping
Loading Chart
SU684-2L-12R
SU684-1R-12L
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 1, Top 2, Top 5
400V 3N~
28 .95
10 .05
9 .46
9 .45
43 .70
41 .09
41 .09
126 .87
L2
Top 3, Oven 1
415V 3N~
28 .95
10 .05
9 .45
9 .45
41 .88
39 .38
39 .38
120 .63
L3
Oven 2, Top 4
380V 3N~
26 .49
9 .20
8 .65
8 .65
41 .80
39 .30
39 .30
120 .40
WITH SALAMANDER
export (wye)
load
voltage total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 1, Top 2, Oven 1
400V 3N~
35 .95
11 .55
12 .8
11 .6
50 .22
55 .86
50 .43
156 .30
12
Top 3, Top 5, Oven 2
415V 3N~
35 .95
11 .55
12 .8
11 .6
48 .13
53 .33
48 .33
149 .79
L3
Top 4, Salamander
380V 3N~
32 .89
10 .57
11 .71
10 .61
48 .03
53 .23
48 .24
149 .51
SU684-2R-12L
SU684-1L-24R
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1phase
L1
Top 1, Top 4, Top 5
400V 3N~
28 .95
10 .05
9 .45
9 .45
43 .70
41 .09
41 .09
125 .87
L2
Top 2, Oven 1
415V 3N~
28 .95
10 .05
9 .45
9 .45
41 .88
39 .38
39 .38
120 .63
LB
Oven 2, Top 3
380V 3N~
26 .49
9 .20
8 .65
8 .65
41 .80
39 .30
39 .30
120 .40
WITH SALAMANDER
export (wye)
load
voltage total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 4, Top 5, Oven 1
400V 3N~ 35 .95
11 .55
12 .8
11 .6
50 .22
55 .65
50 .43
156 .30
L2
Top 1, Top 2, Oven 2
415V 3N~ 35 .95
11 .55
12 .0
11 .6
40 .13
53 .33
48 .33
149 .79
L3
Top 3, Salamander
380V 3N~ 32 .89
10 .57
11 .71
10 .61
48 .03
53 .23
48 .24
149 .51
SU684-2C-12R
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 2, Top3, Top 5
400V 3N~
28 .95
10 .05
9 .45
9 .45
43 .70
41 .09
41 .09
125 .87
L2
Top 1 , Oven 1
415V 3N~
28 .95
10 .05
9 .45
9 .45
41 .88
39 .38
39 .38
120 .63
LB
Oven 2, Top 4
380v 3N~
26 .49
9 .20
8 .65
8 .65
41 .80
39 .30
39 .30
120 .40
WITH SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 3, Top 5, Oven 1
400V 3N~
35 .95
11 .55
12 .8
11 .6
50 .22
55 .65
50 .43
156 .30
L2
Top 1 , Top 2, Oven 2
415V 3N~
35 .95
11 .55
12 .8
11 .6
48 .13
53 .33
48 .33
149 .79
L3
Top 4, Salamander
380V 3N~
32 .89
10 .57
11 .71
10 .61
48 .03
53 .23
48 .24
149 .51
SU684-3R
SU684-1C-24R
SU684-364
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 3, Top 4, Top 5
400V 3N~
28 .95
10 .05
9 .45
9 .45
43 .70
41 .09
41 .09
125 .87
L2
Top 1 , Oven 1
415V 3N~
28 .95
10 .05
9 .45
9 .45
41 .88
39 .38
39 .38
120 .63
L3
Oven 2, Top 2
380V 3N~
26 .49
9 .20
8 .65
8 .65
41 .80
39 .30
39 .30
120 .40
WITH SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 3, Top 4, Oven 1
400V 3N~
35 .95
11 .55
12 .8
11 .6
50 .22
55 .66
50 .43
156 .30
L2
Top 1 , Top 5, Oven 2
415V 3N~
35 .95
11 .55
12 .8
11 .6
48 .13
53 .33
48 .33
149 .79
L3
Top 2, Salamander
380V 3N~
32 .89
10 .57
11 .71
10 .61
48 .03
53 .23
48 .24
149 .51
SU684-3C-12L
SU684-2C-24L
SU684-1C-36L
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 1, Top 2, Top 3
400V 3N~
27 .7
10 .05
8 .2
9 .45
43 .70
35 .65
41 .09
120 .43
L2
Top 4, Oven 1
415V 3N~
27 .7
10 .05
8 .2
9 .45
41 .88
34 .17
39 .38
115 .42
L3
Oven 2, Top 5
380V 3N~
25 .34
9 .20
7 .50
8 .65
41 .88
34 .17
39 .38
115 .42
WITH SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 1, Top 2, Oven 1
400V 3N~
34 .7
11 .55
11 .56
11 .6
50 .22
50 .22
50 .43
150 .8Z7
L2
Top 3, Top 4, Oven 2
415V 3N~
34 .7
11 .55
11 .55
11 .6
48 .13
48 .13
48 .33
144 .58
L3
Top 5, Salamander
380V 3N~
31 .75
10 .57
10 .57
10 .61
48 .03
48 .03
48 .24
144 .31
SU684-1L-36R
SU684-3R-12L
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 1, Top 3, Top 4
400V 3N~
27 .7
10 .05
8 .2
9 .45
43 .70
35 .65
41 .09
120 .43
L2
Top 5, Oven 1
415V 3N~
27 .7
10 .05
8 .2
9 .45
41 .88
34 .17
39 .33
116 .42
L3
Oven 2, Top 2
380V 3N~
25 .34
9 .20
7 .50
8 .65
41 .80
34 .10
39 .30
115 .20
WITH SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 3, Top 4, Oven 1
400V 3N~
34 .7
11 .55
11 .55
11 .6
50 .22
50 .22
50 .43
150 .87
L2
Top 1, Top 5, Oven 2
415V 3N~
34 .7
11 .55
11 .55
11 .6
48 .13
48 .13
48 .33
144 .58
L3
Top 2, Salamander
380V 3N~
31 .75
10 .57
10 .57
10 .61
48 .03
48 .03
48 .24
144 .31
SU684-3C-12R
SU684-2C-24R
SU684-1C-36R
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 2, Top 3, Top 4
400V 3N~
27 .7
10 .05
8 .2
9 .45
43 .70
35 .66
41 .09
120 .43
L2
Top 5, Oven 1
415V 3N~
27 .7
10 .05
8 .2
9 .45
41 .88
34 .17
39 .38
115 .42
L3
Oven 2, Top 1
380V 3N~
25 .34
9 .20
7 .50
8 .65
41 .80
34 .10
39 .30
115 .20
WITH SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 2, Top 3, Oven 1
400V 3N~
34 .7
11 .55
11 .55
11 .6
50 .22
50 .22
50 .43
150 .87
L2
Top 4, Top 5, Oven 2
415V 3N~
34 .7
11 .55
1155
11 .6
48 .13
48 .13
48 .33
144 .58
LB
Top 1, Salamander
380V 3N~
31 .75
10 .57
10 .67
10 .61
48 .03
48 .03
48 .24
144 .31
SU684-3L-12R
SU684-1R-36L
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 2, Top 3, Top 6
400V 3N~
27 .7
10 .05
8 .2
9 .45
43 .70
35 .66
41 .09
120 .43
L2
Top 1 , Oven 1
415V 3N~
27 .7
10 .05
8 .2
9 .45
41 .88
34 .17
39 .38
115 .42
L3
Oven 2, Top 4
380V 3N~
25 .34
9 .20
7 .50
8 .65
41 .80
34 .10
39 .30
115 .20
WITH SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 3, Top 5, Oven 1
400V 3N~
34 .7
11 .55
11 .55
11 .6
50 .22
50 .22
50 .43
150 .87
L2
Top 1 , Top 2, Oven 2
415V 3N~
34 .7
11 .55
1155
11 .6
48 .13
48 .13
48 .33
144 .58
L3
Top 4, Salamander
380V 3N~
31 .75
10 .57
10 .57
10 .61
48 .03
48 .03
48 .24
144 .31
SU684-2R-24L
SU684-2L-24R
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 2, Top 4, Top 5
400V 3N~
27 .7
10 .05
8 .2
9 .45
43 .70
35 .85
41 .09
120 .43
L2
Top 1 , Oven 1
415V 3N~
27 .7
10 .05
8 .2
9 .45
41 .88
34 .17
39 .38
115 .42
L3
Oven 2, Top 3
380V 3N~
25 .34
9 .20
7 .50
8 .65
41 .00
34 .10
39 .30
115 .20
WITH SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 4, Top 5, Oven 1
400V 3N~
34 .7
11 .55
11 .55
11 .6
50 .22
50 .22
50 .43
150 .87
L2
Top 1 , Top 2, Oven 2
415V 3N~
34 .7
11 .55
11 .55
11 .6
48 .13
40 .13
48 .33
144 .68
L3
Top 3, Salamander
380V 3N~
31 .75
10 .57
10 .57
10 .61
48 .03
48 .03
48 .24
144 .31
SU684-3R-24L
SU684-3L-24R
SU684-2R-36L
SU684-2L-36R
NO SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 1, Top 2, Top 3
4000 3N~
26 .45
10 .05
8 .20
8 .20
43 .70
35 .85
35 .65
115 .00
L2
Top 4, Oven 1
415V 3N~
26 .45
10 .05
8 .20
8 .20
41 .88
34 .17
34 .17
110 .21
L3
Oven 2, Top 5
380V 3N~
24 .20
9 .20
7 .50
7 .50
41 .80
34 .10
34 .10
110 .00
WITH SALAMANDER
export (wye)
load
voltage
total kW
kW L1
kW L2
kW L3
A L1
A L2
A L3
A 1 phase
L1
Top 1, Top 2, Oven 1
400V 3N~
33 .45
11 .55
11 .55
10 .35
50 .22
50 .22
45 .00
145 .43
L2
Top 3, Top 4, Oven 2
415V 3N~
33 .45
11 .55
11 .55
10 .35
48 .13
48 .13
43 .13
139 .38
L3
Top 5, Salamander
380V 3N~
30 .60
10 .57
10 .57
9 .47
48 .03
48 .03
43 .04
139 .11