Part # P152 Rev 1 (01/13/10)
Page 7
DIMENSIONS AND SPECIFICATIONS, MODELS SERC, SER-680
S/SU
ERC, ER-680
-ERC = 34” (864mm) wide counter top salamander
-ER-680 = 34” (864mm) wide range mount salamander
S = Sentry series salamander
SU = Sentry series salamander CE marked design
Salamander Suffix Definitions
3"
[76mm]
REAR CABLE
ENTRANCE
34"
[864mm]
16-1/4"
[413mm]
1-1/8"
[29mm]
18"
[457mm]
34-1/4"
[870mm]
20-1/4"
[514mm]
36"
[914mm]
Model
Total Kw Load
TOTAL AMPS
208V/1Ph 208V/3 Ph 240V/1Ph 240V/3 Ph 400 V/3N 415V/3N
SERC, SER-680
wired independently
7
34
29
29
25
15
15
Installation Notes:
Clearances from combustible surfaces should be minimum 7” (178mm) from sides, 2” (51mm) from back .
*Note: 3 phase ratings apply to SERC and SER-680 ordered separately . When a range and salamander are ordered together
it is standard for the salamander to be prewired at the factory to interconnect with the range (single phase) . For further
information on ratings and connection options consult the factory .
KW Ratings
Total kW loading is 7 .0 kW
Model
Shipping
Cu Ft
Lbs/Kg
S/SUERC
11
210/95
S/SUER-686
25
176/80
S/SUER-684
35
209/95