Part Number 4532879 1/15
27
Section 2
Installation
Electrical Installation
DAGER
All electrical connections must be carried out by a
certified electrical contractor, who is responsible for the
correct rating and installation of the induction unit. The
contractor has to comply with all legal safety regulations
and all applicable national and local electrical codes.
n
Warning
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.
n
Warning
This equipment must be positioned so that the plug is
accessible unless other means for disconnection from
the power supply (e.g. circuit breaker or disconnect
switch) is provided.
n
Warning
Observe all safety and warning signs and markings on
the unit.
n
Warning
When residual current circuit breakers are used, it
has to be taken into account, that by switching on an
induction generator to a three phase power supply
system, leakage current can be caused for a short period
due to the asymmetry. This leakage current can activate
the residual current circuit breakers. While choosing
residual current circuit breakers, please note that the
generator generates direct as well as alternating current
in high frequency areas of approximately 20 kHz.
Our recommendation is to choose a residual current
circuit breaker suitable for these requirements. If the
residual current circuit breakers are used as protection
for personnel, the breakers must be in compliance to
the specific national and local regulations for personal
safety devices.
otice
Ensure the supply voltage and the line current match
the specifications given on the serial plate affixed to the
unit. A stable mains supply must be provided.
Wrong voltage will damage the induction unit. Follow
strictly the specifications on the serial plate on the unit.
otice
All cables must be routed, protected and tension free.
otice
The electrician must equip the generator with a mains
cable in accordance with the applicable regulations.
Ensure the mains cable connection is absolutely correct.