190-01639-00
GSU 75 ADAHRS Installation Manual
Rev. 6
Page 5-15
If, upon completion of the Magnetometer Calibration Procedure in either of the two directions, the PFD
displays either the “MAG FIELD AT SITE NOT UNIFORM”, or “MAG FIELD AT SITE DIFFERS
FROM IGRF MODEL” message, then the site contains magnetic disturbances that are too large.
NOTE
The Magnetometer Calibration Procedure must consistently report “CALIBRATION
SUCCESSFUL / SITE IS CLEAN” in both the clockwise and counter-clockwise directions
for the site to be considered acceptable. More than one failure out of ten attempts in a
given direction would be sufficient reason to conclude the site is not acceptable.
A site that is used repeatedly to perform the Magnetometer Calibration Procedure should be re-evaluated
every 12 months, and after any significant construction or placement of magnetic objects (above or below
ground) within 50 meters of the location.
340095
The document reference is online, please check the correspondence between the online documentation and the printed version.